The first and widest screen
Every weld is looked at. Here is exactly what the inspector is looking for
Visual testing is the only method applied to every weld on your steel. It is fast, it needs no power or chemicals, and it catches most of the defects that matter before any other test is booked. Done properly it is not a glance: it is a gauged check of size, profile and surface against the AWS D1.1 acceptance criteria, under good light, at the right time, and written down.
If a weld fails visual inspection, no other test is run on it until it is repaired. VT is the gate every other method waits behind.
Under the lamp
Six weld profiles, two of them acceptable
Cross-sections of a fillet weld on a T-joint and a groove weld on a butt joint. The shape of the weld face and toes is the first thing the inspector reads.
Flat to slightly convex fillet
Full leg size, smooth blend at both toes.
Fillet welds in depthUndercut at the toe
A groove melted into the base metal, measured in depth.
Fillet welds in depthGroove weld with even reinforcement
Reinforcement within limits, blending into both plates.
Groove welds in depthUnderfill or overlap
Face below the plate surface, or weld metal rolled over the toe.
Groove welds in depthWhat the inspector checks
Eight things read on every weld
Each one has an acceptance criterion in AWS D1.1. A weld has to pass all eight before it is released.
Cracks
No crack of any size is accepted. Crater cracks at the stop count too.
Fusion
Weld metal fused to the base metal and between passes, with no cold lap at the toes.
Size and length
Leg size, throat and length checked against the weld symbol on the shop drawing.
Profile
Convexity, concavity and groove reinforcement within the AWS D1.1 profile limits.
Undercut
Depth measured against the limit for the plate thickness and the loading.
Porosity
Visible piping porosity counted and measured along the weld length.
Craters
Every crater filled to the full cross-section of the weld.
Arc strikes and spatter
Arc strikes outside the joint removed and checked; spatter cleaned where coating follows.
Acceptance ruler
Four numbers that show how strict visual acceptance is
0
cracks accepted
Any crack, whatever its size or direction, is rejected.
1 mm
(1/32 in) undercut
Typical limit on material under 25 mm (1 in), statically loaded, with a short allowance for slightly deeper undercut.
0.25 mm
(0.01 in) undercut
Typical limit on cyclically loaded primary members where the weld is transverse to tensile stress.
48 h
wait on Q&T steels
Final visual inspection of welds in quenched and tempered grades such as ASTM A514 waits at least 48 hours, for delayed cracking.
Examples paraphrased from the AWS D1.1 visual acceptance criteria for nontubular connections. Exact limits depend on the edition, the loading and the joint, and the criteria in your specification govern.
The gauge kit
What our QC inspector carries to every weld
Visual testing is a measured check, not an opinion. Each tool answers one question about the weld.
Fillet weld gauges
Leaf gauges read leg size and whether the face is convex or concave.
Multi-purpose weld gauge
Reads reinforcement, undercut depth, throat and bevel angle in one tool.
Hi-lo gauge
Checks alignment and root gap of groove joints before welding.
Temperature indicators
Contact thermometers and temperature crayons for preheat and interpass.
Inspection light
A strong, even light at the weld, with a raking angle for surface detail.
Magnifier and mirror
For craters, toes and welds that cannot be seen straight on.
Camera
Every rejected weld and every closed repair is photographed for the punch list.
Paint marker
Rejected welds are marked on the steel in yellow paint marker, next to the defect.
A valid inspection
Light, distance, a clean surface and the right moment
A visual inspection only counts if the inspector can actually see the weld. These four conditions are set before the gauges come out.
Light
A common reference, ASME Section V Article 9, asks for at least 1,000 lux (100 fc) at the surface.
Distance and angle
The eye within about 600 mm (24 in) of the weld, at no less than 30° to the surface.
Clean surface
Slag and spatter removed, so the inspector sees the weld, not the dirt on it.
The right time
After cooling to ambient, and after the delay the code sets for quenched and tempered steels.
Four sets of eyes
How a weld is signed off at our plant
The steps before, during and after welding are laid out on our weld inspection checkpoint page. This is who looks at the finished weld.
Welder
Checks the weld on completion and cleans it, before it leaves the station.
Foreman
Checks weld size and appearance against the shop drawing.
World Steel QC
Inspects and records every weld in the Welding Inspection Report, and marks any reject.
Your third party
Where you designate one, inspects the same welds at hold points in the plant, by video or on arrival.
Who performs it
Who performs VT on your job
The Inspection and Test Plan both sides agree before production names who performs each test, where it happens and how the results come back to you.
In-house, by World Steel QC
Our QC inspects every weld, to written procedures, with calibrated equipment, at the plant in Vietnam.
Or by the third party you designate
Your QA agency, special inspector or testing firm can perform or witness VT at hold points in our plant, live by video alongside our QC, or on arrival at site.
Agreed in the ITP
Each VT line in the Inspection and Test Plan names the method, extent, acceptance criteria and who performs it, before production starts.
Weld types
The welds VT checks on your steel
Each weld type has its own landing: how it is sized, how we weld it, and how it is inspected.
The other methods
Five more ways we test a weld
Questions
Visual testing questions from US reviewers
Is every weld visually inspected?
Yes. Every weld is visually inspected by World Steel QC against the AWS D1.1 acceptance criteria and recorded in the Welding Inspection Report. Welders and foremen check first, so most issues are fixed before QC sees them.
Can visual inspection replace UT on full-penetration welds?
No. VT sees only the surface. Where the code or your specification requires UT or RT of a CJP groove weld, VT is done first and the volumetric test follows.
Who can perform VT besides your QC?
The third party you designate, such as your special inspector or a testing agency. It can inspect at hold points in our plant, live by video, or on arrival at site.
Which standard sets the visual acceptance criteria?
AWS D1.1, with separate limits for statically and cyclically loaded connections, unless your specification sets other criteria. Seismic welds follow the added rules of AWS D1.8 where it applies.
What happens to a weld that fails VT?
It is marked on the steel in yellow paint marker, logged with a photo, repaired under a qualified procedure, inspected again and closed with a photo in the punch list.
Do you inspect welds before they are painted?
Yes. Visual inspection and any other NDT are completed and accepted before blasting and coating, so nothing is hidden under the paint.
Send the weld schedule your engineer wants inspected
We show in the ITP how every weld is visually inspected, where your inspector can check them, and how the records reach your data book.