Skip to content
Seeking US contractor partners IAS AC472 ACCREDITED ★ METAL BUILDINGS ★ AC472 IAS AC472 accreditedIAS AC472
World Steel USA

Secondary framing

Purlins and girts at the rhythm your panels need

Roll-formed Z and C members that span frame to frame, give every roof and wall sheet a fastening line and steady the frames against uplift. Made in the same plant that fabricates 2,500 t of structural steel a month, and shipped with the frames they bolt to.

Aerial view of a factory frame with purlins and girts in place, framed by World Steel in Thailand
Purlins and girts by World Steel, Thailand

Four members, one rhythm

Choose a profile to see its job

Profile

Z purlin

The workhorse of the roof. Z sections nest over each other at the frames, so a lapped line acts as a continuous beam and uses less steel.

  • Lapped over the frames for continuity
  • Bolted to clips shop-welded on the rafters
  • Gauge and depth set by span and wind zone

C girt

C sections frame the walls and the edges of openings, where a straight back and square ends make neat jambs and headers.

  • Wall girts and door jambs
  • Square ends for clean trims
  • Simple-span or lapped, per design

Eave strut

Sits where the roof meets the wall and carries the last row of roof and wall sheets on one member.

  • Ties roof plane to wall plane
  • Carries gutter and trim lines
  • Sized for the end-zone pressure

Bracing

Rod, cable, angle or portal bracing in the roof and wall planes takes longitudinal wind and seismic forces to the foundation.

  • Rod or cable X-bracing
  • Portal frames where a bay must stay open
  • Flange braces to steady the frame

Spacing follows the wind

Closer where the suction is highest

ASCE 7-22 gives roof corners and edges higher components-and-cladding pressure than the middle. We tighten the purlin line there instead of making the whole roof heavy.

Roof zone

Standard spacing where wind pressure is lowest.

Higher pressure near the eaves and gables, so purlins move closer or go up a gauge.

The highest suction on the roof gets the tightest spacing and the heaviest members.

6 PURLIN LINES IN THIS ILLUSTRATION
8 PURLIN LINES IN THIS ILLUSTRATION
11 PURLIN LINES IN THIS ILLUSTRATION

Illustration. The panel’s tested span and your site’s wind pressure set the real spacing.

Less steel, same strength

Lapped Z purlins work as one long beam

Where Z purlins nest over each frame, the line acts as a continuous beam. Moments drop in each span and the purlins can be lighter than simple-span members.

LAPLAP

How we engineer it for US codes

How it ties into the main frames
Purlins and girts bolt to clips that are shop-welded to the frames. Flange braces running from those members hold the inner flange of the frame in place, which is critical when wind uplift turns compression into tension and back.
What sets the spacing
Spacing is driven by the panel’s tested span for the design pressure. Roof corners, edges and wall ends see higher components-and-cladding pressures and get tighter spacing or heavier gauges.
Continuity
Lapping Z purlins over the frames lets them behave as continuous beams, cutting steel weight. Cold-formed members are designed to AISI S100.
Bracing
Rod, cable, angle or portal bracing in the roof and wall planes delivers longitudinal wind and seismic forces to the foundation.
Warehouse frames with purlins running bay to bay in the Philippines Photo
Steel frame with girts and purlins installed on a warehouse site Photo
Bundles of roll-formed members packed for export at the World Steel plant Photo

Large-project capacity

Every frame’s purlins, at 2,500 t a month

World Steel fabricates 2,500 metric tons (about 2,750 short tons) of structural steel a month in its own IAS AC472-accredited plant in Vietnam, so the steel package of a large US job runs as one order.

2,500 metric tons a month

In the catalog

Secondary framing in the catalog

Rows of roof purlins and rod bracing across a steel frame Photo

Z Purlins

Roll-formed Z members that span between roof frames and overlap at the supports, so each run works as one continuous beam. Made by World Steel in Vietnam Verified
Portal frames and roof purlins silhouetted against the sky Photo

C Purlins

Roll-formed C channels used as purlins, girts and the jambs and headers around wall openings. Made by World Steel in Vietnam Verified
Long warehouse frame running beside a road Photo

Wall Girts

Horizontal Z or C members fixed across the columns to carry the wall panels and their wind load back to the frames. Made by World Steel in Vietnam Verified
Drawn illustration of secondary framing, standing in for a photo of this product Illustration

Eave Struts

The cold-formed member that runs along the top of each sidewall, catching the edge of the roof panels and the top of the wall panels. Made by World Steel in Vietnam Verified
Drawn illustration of secondary framing, standing in for a photo of this product Illustration

Sag Rods

Small steel rods that tie purlins or girts together mid-span, keeping them straight and stopping them from rolling under load. Made by World Steel in Vietnam Verified
Warehouse frame from above, purlins and girts fixed to the rafters and columns Photo

Roof Bracing

Diagonal rods, angles or portal frames in the roof plane that pass lengthwise wind and seismic forces to the braced bays. Made by World Steel in Vietnam Verified
Top-down drone shot of an open steel warehouse frame Photo

Wall Bracing

Rods, angles or portal frames in the sidewalls and endwalls that take lengthwise forces from the roof down to the foundation. Made by World Steel in Vietnam Verified
Drawn illustration of secondary framing, standing in for a photo of this product Illustration

Secondary Connection Components

Purlin and girt clips, flange braces and small connection parts that tie secondary members to the main frames. Made by World Steel in Vietnam Verified
Drawn illustration of secondary framing, standing in for a photo of this product Illustration

Framing Accessories

Miscellaneous framing bits a metal building needs on site: spacers, base angles, angle clips and similar small parts. Made by World Steel in Vietnam Verified

Where it meets the other systems

Primary Structural System

Each purlin and girt bolts to a clip that was welded onto the rafter or column in our shop, and flange braces run from those members to the inside flange of the frame.

Design limit: The frame analysis assumes braces at set points, so clip and brace locations on the drawings must match it exactly. · What gets checked: Confirm every bolt is in and snug and that no flange brace has been left off.

Roofing System

Roof sheets are screwed through, or held by concealed clips, to the purlins below.

Design limit: Purlins can be no farther apart than the panel’s tested span allows at the ASCE 7 roof pressure, which tightens at corners, edges and ridges. · What gets checked: Screw type, spacing and sealing are compared with the approved roof drawings.

Wall & Cladding System

Wall sheets screw to the girts and finish at a base trim along the edge of the slab.

Design limit: The panel’s tested capacity sets the maximum girt spacing, and the wall end zones usually decide it. · What gets checked: Check the screw pattern and that side laps are sealed.

Corrosion Protection

Purlins and girts arrive galvanized from the coil or with a shop paint finish.

Design limit: Zinc coating weight is picked for the exposure, and edges cut after coating get touch-up. · What gets checked: Coil mill certificate showing the coating designation.

Scope, in writing

What we supply and what stays with your team

World Steel, our plant in Vietnam

  • Purlin, girt and bracing design checked with the frame, panel and wind zone together
  • Roll-formed Z and C members, eave struts, clips, sag rods and flange braces as the design needs
  • Shop drawings with member marks and bolt lists, included at no extra cost
  • Bundles tagged by area and packed with the frames, for your US port

The US contractor, our customer

  • Drawing approval, the PE seal and the permit with your Engineer of Record
  • Erection, bolting and plumbing the bracing at site
  • Temporary bracing during erection under your erection plan

Questions from US contractors

Secondary framing questions and answers

6 answers, grouped by topic.

Design 3 answers

What decides purlin and girt spacing?

The tested span of the roof or wall panel at the design wind pressure. Corners, edges and wall ends see higher pressure, so they get tighter spacing or a heavier gauge than the middle of the roof.

Which standard are the cold-formed members designed to?

Purlins, girts and eave struts are designed to AISI S100 for cold-formed steel, with loads from ASCE 7-22 as named by your Engineer of Record.

Why lap Z purlins over the frames?

Lapped Z purlins act as a continuous beam across several frames, which lowers the moment in each span and cuts steel weight compared with simple spans.

Supply 2 answers

Do flange braces and sag rods come with the package?

Yes, when the engineered design calls for them. They are listed on the shop drawings and packed with the members they belong to.

Is secondary framing shipped with the main frame?

Yes. Members are bundled by area and packed in the erection order you give us, so a bay’s frames and purlins can arrive together.

Large projects 1 answer

Can you supply secondary framing for a very large footprint?

Yes. Secondary members come from the same plant that fabricates 2,500 t of structural steel a month, and they are produced alongside the frames so both arrive in the same sequence.

Keep reading

Related pages

Price it or partner with us

Send the panel and the wind speed.

We set purlin and girt spacing with the frame and the panel together, then draw every member for your erector.

Why US contractors price with us

2,500 t / month

Own plant capacity, about 2,750 short tons

IAS AC472

Accredited since 2019, audited twice a year

Up to 5,000 t

Largest single job: Sunpro Steel, 2024

See our largest jobs →

Short project form

Have this system engineered for your site

Ask an engineer directly, or drop the basics below. You get a written scope of supply for a US-code building, checked by engineering first.

Or call +84 902 881 833

Or leave your project details