Scope of the accreditation
Two parts are accredited. Part A covers the Hai Son Industrial Park plant, where structural weldments and welded cold-formed products are made. Part C covers metal building system design at the engineering office on Le Thuc Hoach Street, Ho Chi Minh City. IAS records the in-plant inspection program as meeting IBC §1704.2.5.1 in the 2015, 2018, 2021 and 2024 editions, and Smith-Emery Laboratories (IAS AA-554) visits the plant for periodic inspections.
Part A, fabrication
The plant at Hai Son Industrial Park, Vietnam, where your structural weldments and welded cold-formed parts are made.
Part C, design
The Ho Chi Minh City engineering office on Le Thuc Hoach Street, where your metal building system is designed.
Your design, inside an audited office
Your building is engineered by World Steel staff working under the Part C program, to the criteria your contract documents set. Unless your Engineer of Record names another basis, that means IBC 2024 with ASCE 7-22 loads, and AISC 360 and AISI S100 for the members. The calculation package and drawings go to your Engineer of Record for review and approval.
What Part A puts in place on the shop floor
- No production weld without a qualified procedure (WPS backed by a PQR) and a welder whose qualification is current.
- An Inspection and Test Plan whose hold and witness points you, or your inspector, are welcome to attend.
- Every heat of steel tied to its EN 10204 3.1 mill certificate.
- Results of NDT, dimensional and coating checks collected in the Manufacturing Data Record.
Chapter 17 and the approved-fabricator question
The IBC asks for special inspection of fabricated load-bearing steel. Section 1704.2.5 then lets the building official set aside the in-shop part of that inspection when an approved fabricator does the work. IAS accreditation is widely used by US jurisdictions as grounds for that approval, yet it remains the official’s decision, and local amendments may change how it works. According to the current certificate, World Steel's in-plant inspection program satisfies IBC §1704.2.5.1 in the 2015, 2018, 2021 and 2024 editions. Bring it up at the start of plan review, and expect the field special inspections on your schedule to go ahead as listed.
Verify it in three steps
- Visit the IAS search page for accredited organizations.
- Choose the “Metal Building Systems (AC472)” program and enter World Steel.
- Make sure the listing shows World Steel Construction JSC, includes both Part A and Part C, and is still in date. You can also open the certificate on iasonline.org.
Why it matters to a US owner, contractor or engineer
- Your building official has recognized evidence to weigh when deciding on a §1704.2.5 waiver of shop special inspection.
- Design office and plant answer to the same audited quality system, with inspection records you can request.
- The record goes back to 2019, so you are not the first project to test the system.
- The submittal arrives in a form your Engineer of Record and plan reviewer can work from without translation.
Limits of the accreditation
- Inspections on the jobsite during erection still apply; IAS says so in its own FAQ.
- Erection and assembly are outside it and fall under a different IAS program, AC478. World Steel supplies the steel structure; partner erectors in the US put it up.
- It is neither a permit nor a product or building approval, and it cannot guarantee a permit.
- World Steel becomes the project’s Engineer of Record only if your contract makes it so.