Each purlin and girt bolts to a clip that was welded onto the rafter or column in our shop, and flange braces run from those members to the inside flange of the frame.
- Constraint
- The frame analysis assumes braces at set points, so clip and brace locations on the drawings must match it exactly.
- Standards
- AISC 360 for the frames; AISI S100 for the cold-formed members
- Inspection
- Confirm every bolt is in and snug and that no flange brace has been left off.