Wind design that sizes each roof and wall zone for its own pressure

Wind does not push evenly on a building. A Panhandle thunderstorm, a nor'easter off the Jersey Shore and a chinook down the Front Range all hit hardest at roof corners and wall ends, and an open dock door changes the whole picture. ASCE 7-22 assigns each zone its own pressure, and we size every panel, purlin and fastener in that zone to match.

Rows of roof purlins and rod bracing across a steel frame

Roof uplift, relative

Corner

Edge

Field

Illustrative order only; your values come from ASCE 7-22.

Designed to

ASCE 7-22 under IBC 2024, or the edition your jurisdiction enforces

Checked twice

Frames and bracing (MWFRS), then every panel, purlin and fastener (C&C)

New in ASCE 7-22

Tornado loads for Risk Category III and IV buildings in tornado-prone areas

Sign-off

Wind criteria approved in writing by your Engineer of Record before sizing

ridge field edge long wall: interior zone Plan of the roof (top) and one long wall (bottom). Zone widths come from your building's size and height. wind

The signature of wind design

Four zones, four fastening plans

Each zone gets its own purlin spacing, screw pattern and trim fastening, and the zone map goes on the erection drawings.

  • Corner zones

    Highest suction on the roof. Purlins move closer together, panel screws are spaced tighter and clips are checked for the peak uplift.

  • Edge zones

    A band along eaves and rakes where separating air lifts the panels. Denser fastening than the field, and trims fastened for the same pressure.

  • Field zone

    The middle of the roof, with the lowest uplift. Standard purlin spacing and fastener pattern, still sized for the site wind.

  • Wall end zones

    The last few meters of each wall at the corners carry higher pressure, so girts and screws there are heavier than mid-wall.

Two separate checks

Why a sound frame can still lose its roof

ASCE 7 looks at wind at two scales. Mixing them up is the most common reason a metal building keeps its frames and loses its skin.

Main wind force-resisting system

Frames, rafters, columns and bracing feel pressure averaged over a large tributary area, which smooths out short gusts. Our SAP2000 model sizes them for overall wind together with snow, seismic and collateral loads.

  • Rigid frames and knee joints
  • Roof and wall bracing
  • Column bases and anchor reactions

Components and cladding

Panels, screws, purlins and girts feel brief, concentrated peaks over a few square meters, and those peaks run much higher. A second set of checks sizes every secondary member and fastener for the pressure in its own zone.

  • Roof and wall panels with their screw pattern
  • Purlins, girts, laps and bridging
  • Trims, flashings, doors and framed openings

The zones and fastener patterns are drawn on the erection drawings, so the crew installs what the calculation assumed. See how our wind and seismic design runs.

What sets the number

Six inputs behind the design wind pressure

Each one is fixed for your coordinates and your building, then printed with its source at the front of the calculation package.

Risk category

Schools, shelters and emergency facilities are designed for rarer, harsher wind than a typical warehouse.

Decided by · Owner with the Engineer of Record

Basic wind speed

Pulled for your coordinates and risk category from the ASCE 7-22 hazard data. We print no regional number.

Decided by · Engineer of Record

Exposure category

Open fields, prairie and shoreline (C or D) raise pressure; trees and suburbs (B) lower it.

Decided by · Engineer of Record after a site review

Topography

Ridges, escarpments and hilltops speed the wind up near the crest.

Decided by · Engineer of Record from site contours

Enclosure

Dock doors and other large openings can let wind inflate the building from inside.

Decided by · Architect, from door and window sizes

Geometry

Roof pitch, eave height and plan size all shift the pressure coefficients.

Decided by · Architect and World Steel

Beyond the zone map

Where the building gets extra wind detailing

Canopies and overhangs

Wind loads them from above and below at once, so they get their own uplift design and connections.

Overhead doors

A door must be rated for at least the pressure at its location, and the jambs and header are designed for the door's reactions.

Internal pressure

A dock or hangar door that might be open, or might fail, in a storm makes the building partially enclosed in the calculations, and every load goes up.

Purlin stability

Uplift puts the unbraced purlin flange in compression, so bridging and anti-roll devices go where the calculation shows they are needed.

Large-project capacity

2,500 t of structural steel a month

World Steel fabricates 2,500 metric tons (about 2,750 short tons) of structural steel a month in its own IAS AC472-accredited plant in Vietnam, so a large US package is a normal month, not a stretch.

How large jobs run

Compare suppliers

Six envelope questions to put to any metal building supplier

Print them, send them with your bid invitation, and compare the answers side by side.

  1. Is roof uplift capacity based on a test of the whole assembly or only the panel?
  2. Do the drawings show screw type, size and spacing for each roof and wall zone?
  3. Do purlin and girt sizes change between zones, and is the bracing shown?
  4. How do the door and window pressure ratings compare with the calculated pressure?
  5. Is glazing impact-protected where the site falls in a wind-borne debris region?
  6. How are trims and flashings fastened at eaves, rakes and the ridge?

World Steel answers every one of them on the drawings: zone maps, screw patterns and member sizes per zone, with shop drawings included at no extra charge.

Long warehouse frame running beside a road
Portal frames and roof purlins silhouetted against the sky
Warehouse frame from above, purlins and girts fixed to the rafters and columns
Rows of columns, rafters and purlins inside a large steel building

Delivered

US buildings designed with zone-by-zone wind checks

Designed to US codes, fabricated in our plant in Vietnam and shipped packed in erection sequence.

Asked by US project teams

High-wind design questions

11 answers from our engineers, grouped by topic.

Pressure zones 4 answers

Why do roof corners get more screws than the middle of the roof?

Air separates as it passes a roof edge and creates intense local suction that peaks at the corners. ASCE 7 assigns those zones higher pressures, so purlin spacing tightens and fastener patterns get denser there.

Are the zone widths the same on every building?

No. ASCE 7 sets the width of edge and corner zones from the building's least plan dimension and its eave height, so a tall narrow building and a long low warehouse get different zone maps. We draw yours on the erection set.

Do walls have zones too?

Yes. Wall corners carry higher pressure than mid-wall, so the end bays get heavier girts and tighter screw spacing. Doors and windows in those zones need a higher rating than the same unit placed mid-wall.

What does a canopy add to the wind design?

A canopy is loaded from above and below at the same time, so it carries net pressure far higher than the wall beside it. It gets its own members, connections and back-span check on the frame.

Doors and enclosure 3 answers

When is a warehouse treated as “partially enclosed”?

When one wall has openings that are large compared with the rest of the envelope. Wind can then rush in and lift the roof from below, so the design uses higher internal pressure, or the doors are rated to stay shut under design wind.

Can we design as enclosed and just keep the doors shut in a storm?

Only if the doors are rated for the design pressure and your Engineer of Record accepts that assumption. Doors left open by habit, or a door that fails, change the load on every frame, so the choice is written into the design criteria.

Who supplies wind-rated doors?

Doors, windows and roller shutters come through World Steel partners or your own suppliers, rated by their manufacturers. We design the framed openings and jambs for the reactions those doors deliver.

Code basis and sign-off 4 answers

Will my building need a tornado design?

Only if it is Risk Category III or IV and sits in a mapped tornado-prone area under ASCE 7-22. Typical warehouses and shops are Risk Category II and are unaffected. Storm shelters are a separate matter under ICC 500.

Can you tell me the wind speed for my county?

We print no regional values. Your Engineer of Record pulls the basic wind speed for the exact coordinates and risk category from the ASCE 7-22 hazard data, and that number goes on the first page of our calculations.

Who approves the wind criteria?

Your Engineer of Record approves them in writing before we size anything. World Steel designs and fabricates the steel; drawing approval, the PE seal and the permit sit with the US contractor, our customer.

Is wind design different for a large distribution center?

The method is the same, but long walls and wide roofs give bigger field zones and more repeated bays, so savings from zone-by-zone sizing add up across the job. Our plant fabricates 2,500 metric tons a month, so large footprints are routine.

Keep reading

Related engineering guides

Each one goes deeper on a part of the design this page touches.

All eight US site-condition guides, the standards we design to and the IAS AC472 program are on the engineering & standards hub.

Get an engineer’s eyes on your US building

Share drawings, a sketch or the footprint and site address. We agree the design criteria with your Engineer of Record, then send a written scope and the list of submittals, from a plant that fabricates 2,500 metric tons of structural steel a month.