Transmittal register
Five drawing stages, and who acts at each
World Steel designs and draws. Your Engineer of Record approves and seals. Nothing is cut before the approved set.
Proposal drawings
Design notes, plans, elevations and 3D views of the span, its members and the site it sits on.
You decide on the scheme
World SteelDesign report
Loads, combinations, member checks and connection designs, set out for your engineer to follow.
Your engineer checks the numbers
World SteelApproval drawings
Full drawings for review. Comments are closed and every revision is logged.
Your Engineer of Record reviews, approves and seals
Your EORShop drawings
Every chord, gusset and splice plate with its holes, welds and mark. No extra charge.
Fabrication starts on the approved set
World SteelErection drawings
Piece marks, sequence, bolts and lifting weights, span by span, in the crew’s language on request.
The US contractor, our customer, erects
World SteelRead more: the design report, shop drawings at no extra cost and value engineering.
Design basis
The spec sheet behind a footbridge
Figures in this sheet are from the Guyana bridges. Every job follows the owner’s code and the loads your engineer confirms.
Design code
Designed to the code the owner names, usually the AASHTO guide specification for pedestrian bridges, with AISC 360 for the steel.
Crowd load
Guyana: 4.3 kN/m² (about 90 psf) on the deck, as specified for that job. Your engineer confirms the loads for yours.
Steel grades
Built-up members in Q355B or ASTM A572 Gr 50, with mill certificates traced to each piece.
Welding
Designed to AWS D1.1, with double-sided welds where the drawings call for them.
Camber
Long members cambered, L/500 on the Guyana spans, checked on our shop floor.
Other loads
Wind, temperature, vibration and any vehicle or seismic case the owner names.
The code in detail: pedestrian bridge standards. All codes we design to: US codes and standards.
To start the design
Six inputs we ask for
Span and width
Clear span, walkway width and the number of spans.
Clearances
Height over the road, river or rail below, and any navigation or vehicle envelope.
Code and loads
The design code and the owner’s loads, or ask us to propose them for your engineer.
Site
Location, exposure, supports and access for the crane.
Look
Truss form, enclosure, roof, colour and lighting provisions.
Access
Stairs, ramps or elevator frames at each end.
Records
Every revision, on one screen from the US
Drawings, comments, approvals, fabrication status and shipping stay together in PEB Studio, open to your team and your engineer.
Pedestrian bridge guides
The rest of the footbridge story
Who buys footbridges and why: pedestrian bridges by market and trail and park bridges. The design code behind them: pedestrian bridge standards.
Questions
Footbridge drawings and approvals
Who seals the drawings for a pedestrian bridge?
Your Engineer of Record. World Steel designs and fabricates the steel and prepares the calculations and drawings; your Engineer of Record reviews them, approves them and applies the seal for the permit.
What drawings do you deliver for a footbridge?
A proposal set, a design report, approval drawings, shop drawings for every piece and erection drawings for each span. Shop drawings carry no extra charge.
Which code do you design pedestrian bridges to?
The code the owner names. In the US that is usually the AASHTO guide specification for pedestrian bridges, with AISC 360 for the steel and AWS D1.1 for welding.
What do you need to start the design?
Span and width, clearances, the code and loads, the site, the look you want and how people reach the deck. A general arrangement drawing helps.
Can erection drawings be issued in another language?
Yes. For the Guyana bridges the erection drawings were also issued in Chinese for the crew. Ask when you send the job.
Ready to send your footbridge for design?
Send span, width, clearances and the owner’s criteria. We return a scope, a proposal drawing set and a schedule.