Skip to content
Seeking US contractor partners IAS AC472 ACCREDITED ★ METAL BUILDINGS ★ AC472 IAS AC472 accreditedIAS AC472
World Steel USA
Metal floor deck laid on each level of a steel-framed building

IEBC · ASCE 7-22 · ASCE 41

Seismic expansions and retrofit steel for buildings you already own

Adding bays, a mezzanine or a new wing in earthquake country raises a question a new building never faces: what happens to the old lateral system? The International Existing Building Code answers it. We design additions that stand on their own, and we fabricate retrofit steel to your engineer’s design.

Code
International Existing Building Code (IEBC)
Additions
Self-supporting with a seismic joint, or tied in by design
Retrofit
Braced frames, moment frames and collectors to your engineer’s design

Additions under the IEBC

Independent or connected?

The simplest addition in a seismic region stands on its own. It has its own lateral system and a seismic joint wide enough that the two buildings do not pound against each other, sized from their drifts under ASCE 7-22. The existing building then carries no new seismic load.

When the addition is connected, the IEBC looks at the existing lateral elements. In most cases, if an element’s demand rises by more than ten percent compared with the building without the addition, that element must be shown to meet the current code for wind and seismic. Your Engineer of Record makes that evaluation and decides whether existing frames need strengthening.

Typical projects

Seismic work on existing buildings

New bays on a metal building

Frames matched to the existing profile, with braced bays in the new end wall and a joint or a tie-in designed for seismic.

Mezzanines and platforms

Added seismic weight on the floor, with its own bracing or anchored to frames that are checked for it.

Cranes and heavy equipment

New crane runways and supports change both the weight and the system; frames are checked before the crane goes in.

Rooftop solar and equipment

Weight added to the roof raises the seismic force and can take a frame outside the single-story limits.

Retrofit braced frames

New steel braced frames or moment frames installed inside an existing building to your engineer’s retrofit design.

Collectors and drag struts

Steel members that tie an old roof diaphragm into new lateral frames.

How we work on existing buildings

From field survey to steel that fits

  1. Field survey

    Your team or surveyor measures the existing frames, bolt patterns and elevations. We tell you exactly which dimensions we need.

  2. Design basis

    Your Engineer of Record sets the code path and any evaluation of the existing structure, for example to ASCE 41.

  3. Shop drawings with field checks

    Field-verify dimensions are flagged on the shop drawings, included at no extra charge.

  4. Fabricated to fit

    Members made in our plant in Vietnam, tagged by location and packed in installation order.

Real photos

From our plant in Vietnam

World Steel’s own shop floors and jobs, where the steel for US projects is made. Not stock images.

Steel stair tower attached to the side of a multi-story frame Photo
Stair tower on a multi-story World Steel frame in southern Vietnam.
Mobile crane lifting a member into a multi-story steel frame Photo
Going up beside the plant in Vietnam: World Steel framed its own office building.

How World Steel supports this

Designed to US codes, made in our plant in Vietnam

Additions that fit

New frames detailed to match your existing building and its bolt patterns.

Build to your drawings

Retrofit steel fabricated to your engineer’s design, with shop drawings included.

Drawings for your approval

Our design scope goes to your Engineer of Record to review and approve.

The seismic solution ecosystem

Products and solutions behind this guide

The products we make for this part of a seismic structure, the services that come with them and past World Steel projects, all one click away.

World Steel projects: US codes, Guam, Japan and beyond

Past World Steel work, shown for the structure type. It does not describe the seismic criteria of any one project.

Standards on this page

Read the standard behind it

Each standard page explains what it covers, the edition we reference and how we apply it. We design and fabricate to these standards; they are not certifications.

Keep reading

Related solutions

Questions from US buyers

Retrofit & expansion: questions we hear

Can you extend a metal building made by another manufacturer?

Often, yes. We need the existing drawings or a field survey, and your Engineer of Record decides whether the addition is independent or tied in.

Do you design seismic retrofits?

We fabricate retrofit steel to your Engineer of Record’s design. Evaluating the existing building is theirs; designing new additions can be ours.

Does a mezzanine trigger a seismic upgrade?

It can, if it raises the demand on the existing lateral system beyond what the IEBC allows. Your Engineer of Record checks it before the mezzanine is designed.

Does World Steel provide shop drawings for seismic work?

Yes. Shop drawings come with every project at no extra charge. We design and fabricate the steel structure, and your Engineer of Record reviews and approves the calculations and drawings.

A plain-English summary for US buyers, not the code text and not engineering advice for a specific site. The adopted codes and standards govern, and your Engineer of Record confirms the criteria for each project.

Talk to a seismic engineer

Send the site address, the soil report if you have one, and what the building is for. We confirm the seismic criteria with your Engineer of Record and return a written scope for steel designed to US codes and made in our plant in Vietnam.