Engineering · Design Report

The Design Report: the calculations behind every member of your steel building

The Design Report, also called the design calculation report or structural calculations, is the document that proves each column, rafter, beam, purlin and connection carries the loads at your site. World Steel writes one for every structure it designs and fabricates for the US market.

What it is

The document that proves your steel building stands up

A Design Report is the full set of structural calculations for a steel structure. It starts from the codes and the loads at your site, follows them through the analysis model and ends with a check of every member, every connection and every column base. Drawings show what to build; the Design Report shows why each piece is the size it is.

You may hear it called

  • Design ReportWorld Steel transmittals and the approval set
  • Design calculation reportTitle block of every page
  • Structural calculationsBuilding departments and plan reviewers
  • Calc packageEngineers of Record and detailers
  • Prepared by World Steel's engineering department for every structure we design and fabricate in our IAS AC472-accredited plant in Vietnam, which fabricates 2,500 metric tons (2,750 short tons) of structural steel a month.
  • Designed by one engineer and checked by a second before it is issued, with both noted on the pages.
  • Written for review: the Engineer of Record of the US contractor, our customer, approves it and handles the professional stamp.

Who reads it, and what each of them looks for

  • Engineer of Record

    That loads, codes and assumptions match the project, and that every member and connection works. Approves it and handles the professional stamp.

  • Building department

    Plan reviewers check the structural calculations against the drawings in the permit set before the permit is issued.

  • Foundation engineer

    Column base reactions and anchor rod forces, to design footings, piers and anchorage.

  • Special inspector

    Weld sizes, bolt grades and connection types that the inspection plan has to verify.

  • US contractor, our customer

    A single revision that drawings, shop drawings and site work all follow, with clear scope.

  • Owner and architect

    Proof that the building carries the loads it was bought for, kept in the closeout file.

Why it matters

On a US project, the steel is approved on paper before it is cut

The Design Report is what lets your Engineer of Record sign off, your building department issue the permit and your foundation crew pour concrete while the steel is still in fabrication.

  • No permit without calculations

    US building departments review the structural calculations with the drawings. A clear report with code references shortens plan review and the round of comments that follows.

  • Your engineer takes responsibility

    The Engineer of Record approves the steel design and handles the professional stamp under the rules of your state. They need a report they can follow from input to result.

  • Foundations start early

    Base reactions come with the approval drawings, so footings and anchor rods are designed and poured while the steel is fabricated in Vietnam.

  • Fabrication follows one revision

    Shop drawings and plate cutting start from the approved revision only. Changes go back through the report first, so the steel that ships is the steel that was checked.

  • Value engineering you can verify

    Lighter steel is only useful if it is proven. The report shows the ratios, so your engineer sees where the tonnage went and why each member is the size it is.

  • A record for the life of the building

    The approved report goes into your closeout file. Additions, new equipment loads or a future mezzanine are checked against it years later.

What is inside

Inside a World Steel Design Report, chapter by chapter

Every report follows the same three chapters, so your engineer always knows where to look. Page numbers refer to the 31-page sample you can read online.

Design information

  • Applicable design codes

    p. 5

    The codes and editions used for loads, hot-rolled and built-up steel, cold-formed members, welding and deflection.

    Check: The editions match the code your jurisdiction has adopted.

  • Material specifications

    p. 6

    Each component with its ASTM or equivalent grade and minimum yield strength: plates, rolled shapes, tubes, cold-formed sections, rods, anchor rods and high-strength bolts.

    Check: Grades match the project specification and the general notes on the drawings.

  • Design assumptions

    p. 7

    How the structure works: rigid or pinned column bases, moment connections, how lateral and longitudinal stability are provided.

    Check: Base fixity matches what the foundation design assumes.

  • Load combinations

    p. 7

    Every combination used, written out with its factors, such as 1.2D + 1.6L or 0.9D + 1.0E.

    Check: The set is complete for the loads on your site, including uplift and seismic cases.

  • Design information

    p. 8

    Building size, bay spacing, clear height, roof slope, applied loads, wind speed and exposure, seismic parameters and rainfall.

    Check: Every value agrees with the design basis signed at quotation.

  • Deflection limits

    p. 8

    The limit for each element: rafters, purlins, floor beams, frames, girts and end wall columns, with the load case for each.

    Check: Limits suit the finishes, cladding and cranes on your building.

  • Layout and 3D model

    p. 9

    Column layout, floor framing plans, elevations and an image of the analysis model.

    Check: Grid lines and dimensions match the architectural drawings.

Structure design

  • Analysis input

    p. 12

    The load cases as applied to the model: dead, live, earthquake in each direction, wind, snow and crane loads.

    Check: Loads are applied where they really act, including equipment and collateral loads.

  • Analysis output

    p. 14

    Utilization (stress) ratios drawn along each member of the main frames, beams and joists.

    Check: All ratios are below 1.00; members near 1.00 are expected in an efficient design.

  • Deflection and drift checks

    p. 14

    Each computed deflection beside its allowable value, and story drift in each direction for seismic design.

    Check: Every line reads PASS, under the load level agreed for that check.

Connection design

  • Base plates and anchor rods

    p. 20

    Design forces at the column base, base plate bending, concrete bearing, weld capacity and anchor rod tension, pullout, shear and pryout.

    Check: Anchor rod forces are carried into the foundation design.

  • Frame connections

    p. 25

    End-plate moment connections: geometry, bolt grade and spacing, end plate and column flange behavior, stiffeners, and the governing limit state.

    Check: The connection type matches the frame system, prequalified where seismic design requires it.

Real pages from the sample report

Eight pages from a real World Steel report with the project details removed. Tap a page to enlarge it, or read all 31 pages in the online viewer.

  • Sample Design Report page 1: Cover and revision block

    Cover and revision block

    Revision, date and issue purpose: here REV 00, issued for approval.

  • Sample Design Report page 5: Applicable design codes

    Applicable design codes

    ASCE 7, AISC 360 LRFD, AISI S100, AWS D1.1, IBC and MBMA.

  • Sample Design Report page 7: Assumptions and load combinations

    Assumptions and load combinations

    Pinned column bases, moment frames, four LRFD combinations.

  • Sample Design Report page 8: Design information and limits

    Design information and limits

    Size, bays, loads, wind, seismic, rainfall and deflection limits.

  • Sample Design Report page 14: Frame ratios, deflection and drift

    Frame ratios, deflection and drift

    Stress ratios on the frame, then deflection and drift with PASS.

  • Sample Design Report page 20: Base plate and anchor rods

    Base plate and anchor rods

    Design forces at the column base and every limit state checked.

  • Sample Design Report page 25: Moment connection design

    Moment connection design

    End plate, bolts, stiffeners and column checks with code clauses.

  • Sample Design Report page 29: Seismic connection details

    Seismic connection details

    Bolt grade, protected zone and plate behavior for the moment frame.

Read the whole report

Sample Design Calculation Report, US codes with seismic design

Read free online: a sample of the Design Report for your submittal, from codes and loads to frame and connection checks. Share your details to download.

PDF · 1.7 MB · 31 pages · English

Codes

The codes a Design Report is designed to

The first pages list each code and its edition. On your project they are the editions adopted where the building stands, agreed on the design basis at quotation. World Steel designs to these codes; your Engineer of Record confirms them for the permit.

The sample report, written for a project overseas under US codes, lists ASCE 7-10, AISC 360-10 LRFD, AISC 341-10, AISC 358-10, AISI S100-12, AWS D1.1, IBC 2015 and MBMA 2012. A new US project uses the current adopted editions instead.

All US codes and standards guides

Loads and load combinations

Every load at your site, then every way they can act together

Each load is listed with its value and where it comes from. ASCE 7 then requires them to be combined with load factors, because a roof under full snow, a frame under wind and a column in an earthquake are different worst cases.

  • D

    Dead load

    Self-weight of steel, roof and wall panels, deck and fixed finishes.

  • C

    Collateral load

    Sprinklers, lights, ducts, ceilings and solar panels hung from the roof.

  • L

    Live load

    Occupancy loads for floors and mezzanines from ASCE 7 or your specification.

  • Lr

    Roof live load

    Workers and materials on the roof during construction and maintenance.

  • S

    Snow load

    Ground snow for your site, drifts at steps, parapets and adjoining roofs.

  • R

    Rain load

    Ponding water when drains are blocked, from the design rainfall intensity.

  • W

    Wind load

    Basic wind speed, exposure and risk category, pressure on walls and uplift on the roof.

  • E

    Earthquake load

    Seismic design category, response factor R and importance, both directions.

  • CR

    Crane loads

    Wheel loads, impact, lateral and longitudinal forces from the crane supplier.

Typical LRFD combinations from ASCE 7

The set used on your job is agreed on the design basis and printed in the report. ASD combinations are used instead when your engineer prefers them.

  • 1.4DHeavy dead load, light everything else
  • 1.2D + 1.6L + 0.5(Lr or S or R)Floors and mezzanines
  • 1.2D + 1.6(Lr or S or R) + (L or 0.5W)Roof members under snow
  • 1.2D + 1.0W + L + 0.5(Lr or S or R)Frames under wind pressure
  • 1.2D + 1.0E + L + 0.2SFrames under earthquake
  • 0.9D + 1.0WWind uplift on purlins, anchor rod tension
  • 0.9D + 1.0EOverturning and base uplift

In the sample report

A parking deck in a high seismic zone

Dead load, a deck live load of 2.4 kN/m² (50 psf), a ramp dead load of 4.8 kN/m² (100 psf) and earthquake in both directions, with a special moment frame, R = 8. Four combinations govern:

  • 1.4DL
  • 1.2DL + 1.6LF
  • 1.2DL + 1.0LF + 1.0E
  • 0.9DL + 1.0E
Where wind, snow and seismic loads come from

How to read it

How to read the results, with real lines from the sample

Most of a Design Report is the same idea repeated: what the member or connection has to carry, what the code lets it carry, and the ratio between the two. These six lines from the sample report show how to read them.

  • Utilization ratio on a member

    0.86

    Demand divided by the capacity the code allows. Under 1.00 passes. The sample frame peaks at 0.86 on the rafter and 0.66 on the columns: steel working hard without being overloaded.

    PASS

  • Vertical deflection

    17.24 mm < 41.67 mm

    Computed deflection (0.68 in) against the limit L/240 on a 10,000 mm (32.8 ft) span, 41.67 mm (1.64 in). The check names the combination used: DL + CL + LF.

    PASS

  • Seismic story drift

    30.58 mm < 62.50 mm

    Elastic drift amplified per the code, 0.7 × R × Δs = 0.7 × 8 × 5.46 mm, against 0.025 H on a 2,500 mm (8.2 ft) story. Shown for both directions; the Y direction reads 60.31 mm.

    PASS

  • Base plate and anchor rods

    0.15 and 0.29

    Ratios for the base plate and for the anchor group under the governing column forces, after checking bearing, plate bending, welds, tension, pullout, shear and pryout.

    PASS

  • Moment connection

    0.99

    The global critical strength ratio of an end-plate connection: the lowest margin among all limit states, each listed with its AISC 360 equation or section.

    PASS

  • Check column

    PASS

    Each check ends with PASS. A FAIL never leaves our office: the member is resized and the analysis re-run before the report is issued.

    PASS

Three questions that read any page

  • Which load combination governs? Each result names it, so you can see whether gravity, wind or earthquake sized the member.
  • Is the ratio under 1.00? Demand over capacity. Under 1.00 passes; close to 1.00 means no steel is wasted.
  • Which clause is it checked against? Connection checks cite the AISC 360 equation or section beside each limit state.
Sample Design Report page 14: frame stress ratios, deflection and drift checks

Base reactions

Column base reactions: the page your foundation engineer reads first

A base reaction is the force a column puts on its foundation. The report gives it for each column and each load case: the vertical force (compression or uplift), the shear in each direction and, for fixed bases, the moment. The approval drawings carry the anchor rod plan that goes with them.

Design forces at a pinned column base in the sample report. Negative axial force means compression. US units in brackets.
CaseAxial PuShear Vu2Shear Vu3
Mmax-757 kN (170.2 kips)-40 kN (9.0 kips)160 kN (36.0 kips)
Pmax-878 kN (197.4 kips)-46 kN (10.3 kips)-1 kN (0.2 kips)
V2max-639 kN (143.7 kips)163 kN (36.6 kips)17 kN (3.8 kips)
  • Uplift and shear decide the anchor rods; downward load decides the footing size.
  • Issued with the approval drawings, so footings are designed while the steel is fabricated.
  • Footings, piers and embedment are designed by the foundation engineer on the US side.
  • Base plate and anchor rod checks in the report confirm the steel side of the connection.
Tubular column with a square base plate and bolt holes, crew working behind it Photo
Column with its base plate and anchor-bolt holes, fabricated in the Vietnam plant.
Approval drawings and the anchor rod plan

When you receive it

Where the Design Report sits between quote and warranty

The report is written once the contract freezes the design basis, travels with the approval drawings, is revised until your engineer approves it, and then drives every shop drawing and piece of steel.

  1. TogetherQuotationThe design basis is agreed: codes, loads, limits and the building geometry. Proposal drawings show the scope; the full report is not written yet.
  2. TogetherContract signingThe design basis is frozen as part of the contract, so the report is built on inputs both sides signed.
  3. World SteelApproval drawingsThe Design Report, revision 00, is issued with the approval drawings and the column base reactions, designed by one engineer and checked by a second.
  4. Your teamReview and commentsYour Engineer of Record reviews the report and returns comments. We answer each one in writing and re-issue as revision 01, 02 and so on.
  5. Your teamApproval and permitYour engineer approves the report and handles the professional stamp; the US contractor files it with the permit set.
  6. World SteelShop drawingsShop drawings are detailed from the approved revision. Member sizes, bolts and welds match the report one to one.
  7. World SteelFabricationCutting, fitting and welding follow the shop drawings, so the approved calculations reach every piece mark.
  8. World SteelHandover and warrantyThe approved report sits in the engineering volume of the handover package and in our records for future changes.

Who does what

We design and write the report. Your engineer approves it.

World Steel supplies the steel structure: design, fabrication and delivery. It does not erect and does not stamp drawings or calculations. This is how the Design Report splits on a US job.

  • World Steel

    • Designs the steel structure to the codes and design basis in the contract
    • Prepares the Design Report, base reactions and approval drawings, with a second engineer checking
    • Answers every review comment in writing and re-issues the revision
    • Details shop drawings and fabricates from the approved revision
  • Engineer of Record of the US contractor

    • Reviews the Design Report with the approval drawings
    • Approves it and handles the professional stamp under state rules
    • Coordinates the steel with the foundations and the rest of the building
  • US contractor, our customer

    • Files the permit set with the building department
    • Has the footings and anchor rods designed from the base reactions
    • Erects the steel and manages special inspection on site

A reviewer's checklist

What Engineers of Record usually check first. We run the same list before a report leaves our office.

  • Code editions match the code adopted where the building stands
  • Risk category, wind speed, exposure, snow and seismic values match the site
  • Collateral, equipment and future loads are included
  • Load combinations cover uplift, overturning and seismic cases
  • Base fixity matches the foundation design
  • Deflection limits suit the cladding, finishes and cranes
  • Every ratio is under 1.00 and every check reads PASS
  • Material grades match the specification and general notes
  • Connection types match the frame system, prequalified where required
  • Base reactions are given for each load case, not only the totals

Questions from US contractors and engineers

Questions about the Design Report

What is a structural Design Report?

It is the set of structural calculations for a steel building: the codes, materials, loads and load combinations used, the analysis model, the check of every member and connection, deflection and drift, and the column base reactions. World Steel issues one for every structure it designs and fabricates.

Is a Design Report the same as structural calculations?

Yes. Building departments usually say structural calculations, engineers often say calc package, and our title block says Design Calculation Report. They all mean the document that proves the steel works.

Who approves the Design Report on a US project?

The Engineer of Record of the US contractor, our customer. They review it with the approval drawings, approve it and handle the professional stamp under the rules of their state. World Steel designs and fabricates the steel and answers every review comment.

Does World Steel stamp the calculations?

No. World Steel prepares the calculations and drawings. The professional stamp and the permit submittal stay with the US contractor and its Engineer of Record.

When do we receive the Design Report?

With the approval drawings and the column base reactions, right after the contract is signed and the down payment is received. It is revised after each round of review comments until your engineer approves it.

Which codes is the steel designed to?

To the editions of the IBC and ASCE 7 adopted where your building stands, with steel members to AISC 360, cold-formed purlins and girts to AISI S100, welding to AWS D1.1 and serviceability guided by IBC and the MBMA manual. Seismic projects add AISC 341 and AISC 358. The editions are written on the first pages of the report.

Can the report use ASD instead of LRFD?

Yes. The method is agreed on the design basis. Most of our reports use LRFD, and ASD is used when your Engineer of Record prefers it.

What does a ratio of 0.95 mean?

The member uses 95 percent of the strength the code allows under its worst load combination. Anything under 1.00 passes. Ratios close to 1.00 show an efficient design; they are not a warning.

What are base reactions and who uses them?

The forces each column puts on its foundation for each load case: vertical load, uplift, shears and any moment. Your foundation engineer uses them to design footings, piers and anchor rods.

Are base reactions issued before the full approval set?

They come with the approval drawings, so your foundation engineer can start right after award. If your schedule needs them earlier, tell us at the quote stage and we plan the design order around it.

What happens if our engineer has comments?

We answer each comment in writing, update the model and the drawings, and re-issue the report as the next revision. Shop drawings start only from the approved revision.

Is the report in metric or US units?

Our analysis works in SI units, millimeters and kilonewtons, and the drawings show the dimensions your project needs. If your engineer needs results in US units, agree it on the design basis at the quote stage.

Does the report cover the foundations?

No. It gives the base reactions and the anchor rod forces. The footings, piers and anchorage embedment are designed by the foundation engineer on the US side.

Can I see a real Design Report before I award?

Yes. The download center has a real 31-page World Steel Design Report for an elevated parking deck in a high seismic zone, with project details removed and a small SAMPLE box on each page. Read it free online, or share your details to download the PDF.

Does the report change if we add a mezzanine or equipment later?

Any new load is checked against the approved model. Tell us before fabrication and we revise the report; after handover, the approved report in your closeout file is the starting point for the check.

Who checks the calculations inside World Steel?

Every report is prepared by a design engineer and checked by a second engineer before it is issued, with both noted on the pages.

Send your drawings, get a design basis you can approve

Share your plans, site and specification. Our engineers confirm the codes and loads with you, then design the steel with a Design Report your Engineer of Record can follow.