Skip to content
Seeking US contractor partners IAS AC472 ACCREDITED ★ METAL BUILDINGS ★ AC472 IAS AC472 accreditedIAS AC472
World Steel USA
Welder beside a deep built-up girder running through the automatic line

A deep plate girder going through automatic welding at World Steel, Vietnam.

PAUT of critical welds

Phased array UT: the whole weld scanned, imaged and saved for your reviewer

Sectorial, encoded scans of thick and critical CJP welds, performed in-house or by the third party you designate, at the pace of a plant that fabricates 2,500 metric tons of structural steel a month.

Many beams, one saved picture

One probe, dozens of beam angles, and a scan you can open again next month

A phased array probe holds many small elements in one housing. By firing them a few billionths of a second apart, the instrument steers and focuses the beam electronically, sweeping through a fan of angles without moving the probe. Run along the weld on an encoder, it builds a picture of the whole joint, position by position, and saves it as a data file. Your reviewer sees what the technician saw, not only what was written down.

Conventional UT leaves you a report. PAUT leaves you the scan.

40° root55° mid-wall70° cap PHASED ARRAY PROBE

Four ways to see one scan

S-scan, B-scan, C-scan and A-scan from the same data

Because the scan is encoded and saved, the same data can be cut into a cross-section, a side view, a plan view or a single trace, by the technician today or your reviewer later.

S-scan (sectorial)

A fan of angles from one probe position: a cross-section of the weld, with the flaw drawn where it sits.

B-scan

A side view through the thickness along the scan line.

C-scan

A plan view of the weld length, showing where along the joint indications lie.

A-scan

The single echo trace at any point, the same signal conventional UT shows.

0 mm125 mm250 mm375 mm500 mm625 mm750 mm875 mm1000 mm

Side by side

Conventional UT and phased array, compared

Both use the same physics and the same acceptance thinking. The differences are in coverage, the record you keep and what it takes to set up.

AspectConventional UTPhased array UT
Beam anglesOne fixed angle per probe; change probes to change angleA sweep of angles from one probe, for example 40° to 70°
CoverageRaster scanning by hand across the weldLine scan along the weld covers the volume in fewer passes
RecordWritten report of indications foundEncoded data file of the whole scan, kept for review
Flaw pictureEcho height and sound path, interpreted by the technicianAn image of the cross-section with the flaw in place
SetupQuick to set up, simple equipmentScan plan, focal laws and calibration take longer
Code standingThe standard AWS D1.1 UT procedureAn advanced technique under AWS D1.1, used with the Engineer’s approval
TechnicianQualified in conventional UTQualified in UT plus PAUT-specific training

Where it pays off

Four cases where PAUT earns its setup time

Thick CJP welds

Heavy flanges, box column corners and transfer girders, where several angles are needed to cover the joint.

Many identical welds

A large job with repeated splices, where a scan plan set once is run on every joint.

Reviewers who want the data

Owners, QA agencies or insurers who want to re-read the scan, not only the report.

Sizing a flaw

When the Engineer allows flaw sizing instead of automatic repair, the image gives height and position.

Finished columns with base plates resting on shop rails Photo
Finished columns laid out for dimensional checks, World Steel, Vietnam.
Stiffened heavy plate girders resting on shop supports Photo
Heavy plate girders with stiffeners, fabricated by World Steel in Vietnam.
Welder beside a deep built-up girder running through the automatic line Photo
A deep plate girder going through automatic welding at World Steel, Vietnam.

Approval path

From written procedure to an ITP line

Under AWS D1.1, phased array is an advanced UT technique used with the Engineer’s approval. These four steps happen before the first production scan.

Written procedure

Probe, wedge, focal laws, scan plan, calibration and acceptance criteria, in one document.

Qualified on mockups

The procedure is proven on mockup welds with known reflectors, showing the beam reaches the whole joint.

Engineer’s approval

Your Engineer of Record approves PAUT, and the acceptance criteria, before production testing starts.

Written into the ITP

Which welds get PAUT, who performs it, and how the data files are delivered.

What you receive

Six things stored with every scan

A saved scan is only useful if it can be re-read. Each file carries what a reviewer needs to open it, line it up with the steel and check the settings.

  • Weld ID, piece mark and scan start point
  • Encoder position along the weld
  • Focal laws, angles and probe offset
  • Calibration and sensitivity settings
  • Indications with length, height and depth
  • Technician, date and instrument serial

Who performs it

Who performs PAUT on your job

The Inspection and Test Plan both sides agree before production names who performs each test, where it happens and how the results come back to you.

In-house, by World Steel QC

Our QC performs PAUT to the extent your specification assigns to the fabricator, to written procedures, with calibrated equipment, at the plant in Vietnam.

Or by the third party you designate

Your QA agency, special inspector or testing firm can perform or witness PAUT at hold points in our plant, live by video alongside our QC, or on arrival at site.

Agreed in the ITP

Each PAUT line in the Inspection and Test Plan names the method, extent, acceptance criteria and who performs it, before production starts.

Weld types

The welds PAUT checks on your steel

Each weld type has its own landing: how it is sized, how we weld it, and how it is inspected.

Questions

Phased array ultrasonic testing questions from US reviewers

Is PAUT accepted under AWS D1.1?

AWS D1.1 allows advanced UT techniques such as PAUT when the Engineer approves them, using a written procedure qualified on mockups and the acceptance criteria the Engineer accepts. Agree it before production testing starts.

Who performs PAUT on our job?

World Steel QC in-house, or the third party you designate. Either way, the procedure, the scan plan and the data delivery are written into the ITP.

Will PAUT replace the code-required UT?

It can be used for it when your Engineer of Record approves it as the method. Where AISC 360 assigns the testing to quality assurance, your QA agency decides how it tests.

Do we receive the scan files?

Yes, when PAUT is specified the encoded data files can be delivered with the report for each weld, together with the details needed to open and read them.

Why is PAUT not used on every weld?

It takes longer to set up and needs more specialized equipment and training, so it earns its place on thick, repeated or critical welds. Conventional UT stays the standard for the rest, and the quote shows which welds get which.

What is TOFD, and is it the same?

Time-of-flight diffraction is another advanced UT technique, often used alongside PAUT for accurate flaw height. It needs its own procedure and approval in the same way.

Ask for PAUT on the welds that matter most

Tell us which welds and what data your reviewer wants. We prepare the procedure for your Engineer’s approval and plan the scans with production.