Wind
Often governs in
Gulf and Atlantic coasts, the Great Plains and open exposures
What it sizes
Purlins, girts, fasteners, frames, bracing and anchorage against suction and uplift
The engineering problem
Across the US a steel structure is usually governed by one of three things. A light steel frame attracts far less seismic force than concrete, so wind or snow often sets member sizes, but brittle connections can still fail in an earthquake. We run every ASCE 7-22 combination and design each element for the case that governs.
Often governs in
Gulf and Atlantic coasts, the Great Plains and open exposures
What it sizes
Purlins, girts, fasteners, frames, bracing and anchorage against suction and uplift
Often governs in
Northern states, the Rockies, the Northeast and high elevations
What it sizes
Rafters, purlins and roof steps where snow piles, slides or drifts
Often governs in
California and the West Coast, the Intermountain West, Alaska and the New Madrid zone
What it sizes
Bracing, connections, drift and anchorage, and the ductility of the whole system
Designed to: IBC ASCE 7-22 AISC 360 AISC 341 AISI S100 AWS D1.8
Our design sequence
Agree the criteria first
Risk category, basic wind speed for the site coordinates, exposure category, topographic factor and enclosure classification go into a written design basis your Engineer of Record signs off.
Run the frame analysis
Rigid frames, bracing and wind columns are modeled in SAP2000 for every ASCE 7-22 combination, including net uplift where suction beats the dead load.
Zone the roof and walls
Components and cladding pressures climb at corners, eaves and ridges, so purlin spacing, girt spacing and fastener patterns change zone by zone.
Design the openings
A failed overhead door turns an enclosed building into a partially enclosed one. Door design pressures, jamb and header framing and, in wind-borne debris regions, opening protection are part of the package.
Check tornado loads where required
ASCE 7-22 adds tornado design for Risk Category III and IV buildings in the tornado-prone regions it maps. We apply it when your occupancy and site call for it.
Trace the uplift path
Panel to purlin, purlin to rafter, rafter to column, column to anchor rod: each connection is checked, and base reactions go to your foundation engineer in kN and kips.
Start from the ASCE 7-22 ground snow
ASCE 7-22 maps ground snow by site and risk category. State or county case-study values are used where your jurisdiction requires them.
Balanced and unbalanced roof snow
Flat roof snow, exposure and thermal factors, and the unbalanced case on gable roofs are each checked against the frame.
Drift at steps and parapets
Snow drifting against a higher roof, parapet or rooftop unit is calculated and the purlins and rafters under the drift are reinforced.
Sliding snow and adjacent buildings
Snow sliding off a higher roof onto a lower one, or onto a new building beside an existing one, is added where geometry allows it.
Rain-on-snow and ponding
Low-slope roofs are checked for rain-on-snow surcharge and for ponding stability of the secondary framing.
Find the Seismic Design Category
Mapped spectral values from ASCE 7-22, the site class in your geotechnical report and the risk category set the SDC, from A in much of the East to D, E or F near active faults.
Pick a permitted system
Ordinary or intermediate moment frames, or braced frames, are selected within the height limits and system rules ASCE 7 gives for that category.
Apply AISC 341 where required
When the system calls for seismic detailing, members and connections are proportioned so yielding happens where it was planned and connections stay stronger than the parts they join.
Weld to AWS D1.8
Demand-critical welds in seismic force-resisting frames are made with AWS D1.8-qualified procedures and welders.
Check drift and P-delta
Story drift and second-order effects are verified, with extra attention to mezzanines, crane runways and rooftop units.
Size the anchorage
Base plates, anchor rods and brace connections are designed for the larger of the wind and seismic reactions.
Analysis in SAP2000; the 3D model, connections and drawings in Tekla Structures, with an IFC export for your BIM coordination.
Across the United States
A general guide only. The governing case on your job comes from your exact coordinates, risk category and soils report, never from a state average.
Steel solutions by state| Region | Wind | Snow | Seismic | What to watch |
|---|---|---|---|---|
| Gulf Coast and Florida | ●● | ○ | ○ | Hurricane winds and wind-borne debris regions |
| Atlantic seaboard | ●● | ● | ○ | Coastal wind, with snow in the mid-Atlantic and New England |
| Great Plains and Texas Panhandle | ●● | ● | ○ | Open exposure; tornado loads for critical facilities |
| Upper Midwest and Great Lakes | ● | ●● | ○ | Ground snow and drift at roof steps |
| Rocky Mountains and high elevations | ● | ●● | ● | Heavy snow; elevation and site studies matter |
| California and the Pacific Northwest | ● | ● | ●● | High seismic design categories near active faults |
| New Madrid and Charleston zones | ● | ● | ●● | Seismic detailing in otherwise moderate climates |
●● often governs · ● often checked · ○ rarely leads
Lessons from damage surveys
Engineering reviews after US hurricanes, tornado outbreaks and heavy snow winters keep finding failures in the same places.
Tighter purlin spacing and added fasteners in high-suction zones, with eave and rake trims fixed so they cannot start a peel.
Doors specified for the same design pressure as the building, and framed openings designed for the door reactions.
Drift loads at parapets, roof steps and adjacent buildings are calculated, and framing is reinforced where the drift lands.
Coatings and fastener finishes chosen for coastal air, de-icing salts or process exposure, because a corroded screw has lost capacity.
Every brace rod, flange brace and connection is shown with its piece mark on the erection drawings, so nothing is left in the crate.
Anchor rod plans and base reactions are issued early, so the foundation is designed for real uplift and shear.
Transparency
We do not publish one wind speed, snow load or seismic value for a state, because each depends on the exact site and risk category. Your calculations name every input and its source.
We never sell a building as hurricane-proof, tornado-proof or earthquake-proof. Real performance depends on the design criteria, the foundation, the erection work and the maintenance that follows.
World Steel designs, fabricates and supplies the steel structure. Your Engineer of Record reviews and approves our calculations and drawings, and the US contractor, our customer, handles the PE seal, the permit, the foundations and the erection.
Asked by US contractors
The ASCE 7-22 basic wind speed for your site coordinates and the building’s risk category, confirmed by your Engineer of Record. A fire station and a warehouse on the same road can carry different values.
Yes. Ground snow load, flat roof snow, drift at steps and parapets, sliding snow, unbalanced loads and rain-on-snow are all checked where ASCE 7-22 requires them.
SAP2000 for structural analysis and Tekla Structures for the 3D model, connections, shop drawings and erection drawings. An IFC export is available for your BIM coordination.
Yes. We prepare the calculation package and drawings for your permit set. Your Engineer of Record reviews and approves them, and the PE seal and the submittal stay with the US contractor, our customer.
Yes. Where the system requires seismic detailing, members and connections follow AISC 341, and seismic frames are welded with AWS D1.8-qualified procedures and welders.
Value engineering starts from the governing load case, not from a safety margin added everywhere. Every alternative comes with calculations, and your Engineer of Record decides.
Keep reading
World Steel designs, fabricates and supplies the steel structure. You, the US contractor and our customer, erect it, and with your Engineer of Record approve the drawings and handle the PE seal and the permit.
Share the site address, occupancy and drawings. Our engineers set out the ASCE 7-22 design basis for your Engineer of Record and size the steel to the case that controls.