From occupancy to hours
How a steel frame gets its fire-resistance rating
The chain starts with what the building is for. The architect sets the occupancy group, then picks a construction type from IBC Chapter 6 that allows the height and floor area the owner wants. Type I and Type II are the noncombustible types used for most steel buildings, and each comes in a protected and an unprotected version.
IBC Table 601 then gives the rating, in hours, for each building element: the primary structural frame, bearing walls, floors and roofs. Section 703 says how a rating is proven, normally by a fire test to ASTM E119 or UL 263, and Section 704 sets how structural members are protected, including the rule that columns are protected individually and that a member holding up a rated floor or wall needs at least the same rating.
Other parts of the code add ratings of their own: fire walls and fire barriers, exterior walls close to a property line, shafts and exit stairs, and the extra rules for high-rise buildings in Section 403. Local amendments can change any of it, so the edition and amendments your jurisdiction enforces always come first.
IBC 2024 Table 601, steel types only
Ratings for the primary structural frame, floors and roofs
Hours of fire resistance by construction type, as a plain-English summary. Footnotes allow reductions, for example for roof-only framing, and your architect confirms the type and every value.
| Construction type | Primary structural frame | Floor construction | Roof construction |
|---|---|---|---|
| Type IA | 3 hours (2 hours where it supports a roof only) | 2 hours | 1½ hours |
| Type IB | 2 hours (1 hour where it supports a roof only) | 2 hours | 1 hour |
| Type IIA | 1 hour | 1 hour | 1 hour |
| Type IIB | No rating required | No rating required | No rating required |
| Type IIIA and VA | 1 hour | 1 hour | 1 hour |
| Type IIIB and VB | No rating required | No rating required | No rating required |
Good news for many metal buildings
When steel needs no fire protection at all
Fire protection is a cost to justify, not a default. Many single-story steel buildings carry no rating.
Type IIB buildings
Most single-story warehouses, plants and retail boxes are built as Type IIB, where the frame needs no rating. Sprinklers and frontage let the building grow without changing the type.
High roofs
In many occupancies the code waives protection for roof framing where every part of the roof is 6 m (20 ft) or more above the floor below. Storage, mercantile and hazardous occupancies are among the exceptions.
Separation, not protection
Sometimes a fire wall, a fire barrier or more distance to the property line solves the problem better than coating every column. That choice belongs to your architect.
Where ratings appear
Multi-story offices, hospitals, schools, hotels, parking, high-rise and mixed-use buildings, and industrial buildings with hazardous occupancies or owner insurance rules.
Two words that change the thickness
Restrained and unrestrained ratings
Restrained
The surrounding structure resists the thermal expansion of a beam or floor in a fire. Many steel-framed floors qualify, and listed designs usually need less protection for a restrained rating.
Unrestrained
The member is free to expand and rotate, as for simply supported beams at some supports. Unrestrained ratings need more protection for the same hours.
Who decides
The classification follows the guidance in ASTM E119 and is the design team’s call. It must be shown on the drawings, because it changes the thickness the applicator puts on.
The performance route
AISC 360 Appendix 4 and calculated fire resistance
Tested and listed designs are the prescriptive route most projects use. AISC 360-22 Appendix 4, Structural Design for Fire Conditions, adds a way to show by analysis how a steel structure behaves in a defined fire, using the elevated-temperature properties of the steel. It is used on large or unusual buildings, such as atriums, exposed steel and long-span roofs, where a fire engineering study can reduce or target the protection.
IBC Section 722 also allows calculated fire resistance for some steel members, and AISC Design Guide 19 explains how ratings, listings and calculations fit together. Both routes need the building official’s acceptance, and both are the work of the design team. We supply the member sizes, weights and section data that their calculations need.
Two standard fires
The building fire and the hydrocarbon fire
ASTM E119 and UL 263 climb steadily over hours. UL 1709 reaches about 1,093 °C (2,000 °F) within five minutes. Protection is tested, and listed, against the fire it will face.
Real photos
From our plant in Vietnam
World Steel’s own shop floors and jobs, where the steel for US projects is made. Not stock images.
How World Steel supports this
Designed to US codes, made in our plant in Vietnam
Ratings captured at kickoff
Construction type, hours and restrained or unrestrained status are recorded for each member type before design starts.
Section data for the team
Weights, heated perimeters and section factors for every member, ready for the protection schedule.
Shop drawings, included
Rated members and their protection are flagged on the shop drawings at no extra charge.
The fire protection ecosystem
Products and solutions behind this guide
The products we make for this part of a seismic structure, the services that come with them and past World Steel projects, all one click away.
Products made in our plant in Vietnam
Solutions that come with it
World Steel projects: process plants, healthcare, multi-story
Photo
Photo
Past World Steel work, shown for the structure type. It does not describe the seismic criteria of any one project.
Standards on this page
Read the standard behind it
Each standard page explains what it covers, the edition we reference and how we apply it. We design and fabricate to these standards; they are not certifications.
Keep reading
Related solutions
Questions from US buyers
US fire-resistance requirements: questions we hear
Does every steel building in the US need fireproofing?
No. Many single-story buildings are Type IIB, where the frame needs no rating. Ratings come from the construction type, the occupancy, the height and area, separations and local amendments.
Who decides the fire-resistance rating of my steel frame?
The architect and fire protection engineer, from the building code your jurisdiction enforces, with the Engineer of Record. The building official accepts it at permit.
Is a sprinklered building exempt from fire-resistance ratings?
Not automatically. Sprinklers allow more height and area for a construction type and some trade-offs, but the type still sets the ratings.
Can a fire engineering study replace listed designs?
Sometimes. AISC 360 Appendix 4 and IBC alternative means let the design team show performance by analysis, subject to the building official’s approval.
Are shop drawings included for fire-rated steel?
Yes. Shop drawings come with every project at no extra charge, with the rating, protection system and listed design shown for each rated member. Your Engineer of Record reviews and approves the structural drawings.
A plain-English summary for US buyers, not the code text and not engineering advice for a specific site. The adopted codes and standards govern, and your Engineer of Record confirms the criteria for each project.
Planning fire-rated structural steel?
Send the drawings, the specification and the fire protection schedule. We confirm the listed systems and primer with your team and return a written scope for steel designed to US codes, made in our plant in Vietnam and prepared, or coated, for its fire protection.