QP 3
A shop painting operation has been assessed for its procedures, equipment, records and people.
- When a US spec asks for it
- Shop-coated steel for bridges, transit and owners with their own coating rules.
Where it sits in the US code stack
Where it governs in your building
Companies and people, certified separately
AMPP certifies two different things: painting companies, through its QP programs, and individual people, through inspector and applicator certifications. A specification can ask for either. This map shows what each one proves and when US owners tend to ask for it.
Companies · QP programs
A shop painting operation has been assessed for its procedures, equipment, records and people.
A field painting contractor can prepare and coat complex industrial structures on site.
A field contractor can remove hazardous coatings, such as lead paint, safely.
A coating inspection company has the procedures and qualified inspectors to inspect coating work.
People · certifications
An individual has passed AMPP coating inspector training and exams at a stated level.
A blaster or painter has shown the skills in the joint applicator standard SSPC-ACS 1/NACE No. 13.
World Steel applies AMPP, SSPC and NACE standards in its own paint shop. Our coating inspectors hold FROSIO Level III and BGAS painting inspector qualifications, and every coating hold point is open to your inspector. We hold no AMPP QP certification and no AMPP inspector certification; a requirement for either is agreed before award.
16 answers from our engineers
What owners, engineers and coating inspectors ask about AMPP on steel coated in our plant: the merger, how standards are cited, inspector and QP programs, and how World Steel works to them.
The Association for Materials Protection and Performance, formed in 2021 when NACE International and SSPC joined. It publishes the coating and corrosion standards both bodies wrote and runs their training and certification programs.
Yes. The documents carry on under AMPP with their numbers and requirements, and they are revised over time like any standard. A specification that cites SSPC-SP 10 or NACE No. 2 still means near-white blast.
A standard SSPC and NACE wrote together before the merger and published under both numbers, such as SSPC-SP 10/NACE No. 2 for near-white blast or SSPC-SP 6/NACE No. 3 for commercial blast.
By document number and edition, in the form the owner's template uses. What matters is that each document is identifiable; we list them all back to you before fabrication either way.
Checks that the steel is prepared, coated and measured as the specification says: conditions, cleanliness, profile, film thickness and repairs, at the hold points in the inspection plan, and signs the acceptance.
Usually the owner or the Engineer of Record, sometimes through the US contractor. The inspector works for the party that pays, which keeps the inspection independent of the paint shop.
Yes. Hold points can be witnessed in person in our plant or remotely, with live video and the readings posted in PEB Studio. Many owners combine a visit for the first members with remote checks after.
Our painters are trained and certified by the paint manufacturer whose products they apply. AMPP applicator certification of our crew is not claimed.
FROSIO Level III and BGAS painting inspector, two coating inspector schemes used worldwide. They check every hold point in our plant. They are not AMPP certifications, so where a specification names an AMPP-certified inspector, that inspector is appointed by you and witnesses alongside ours.
QP 1 assesses field painting contractors who coat structures on site. QP 3 assesses shop painting operations, where steel is coated before it ships.
No. We apply AMPP and SSPC standards in our own paint shop with full records and inspector access. If your specification requires QP 3, raise it before award so we can agree how it is met.
That depends on the specification. Field touch-up and field coats are the US contractor's scope, so any field qualification it asks for applies to the contractor's painters.
The surface preparation standards, mostly SSPC-SP 1, SP 10 and SP 6, the SSPC-VIS 1 photographs, SSPC-PA 2 for film thickness and SSPC-Guide 15 where salt testing is specified.
We send a written question before fabrication. The stricter requirement usually governs, but the Engineer of Record decides, and the answer goes onto the coating schedule.
Systems from Jotun, PPG, Carboline, Hempel, Nippon Paint and International Paint (IP). The products carry UL certification and sell across the US, so touch-up paint is easy to buy near the job.
Galvanizing itself follows ASTM A123. AMPP documents come in when galvanized steel is painted, for example the SSPC-SP 16 sweep blast before a duplex system.
More answers on every US code we design to: search all standards questions.
Before and after 2021
| Topic | Before 2021 | Since 2021 |
|---|---|---|
| Publisher | Two bodies, SSPC and NACE International | One body, AMPP |
| Surface preparation | SSPC-SP numbers, many shared as joint SSPC/NACE standards | Same numbers and requirements, published by AMPP |
| Corrosion and lining practice | NACE standard practices | Carried on by AMPP as they are revised |
| Coating inspectors | NACE CIP or SSPC inspector programs | AMPP coating inspector certifications, alongside FROSIO and BGAS used worldwide |
| Painting contractors and shops | SSPC QP programs | AMPP QP programs |
Four kinds of AMPP document
A coating specification usually cites a mix of these. Each does a different job, and the specification decides which ones are binding.
How clean the steel must be before coating: SP 1 solvent cleaning through SP 10 near-white and SP 5 white metal blast.
How a result is checked, such as SSPC-PA 2 for dry film thickness or holiday testing of linings.
Advice the specification can make binding, such as SSPC-Guide 15 on testing soluble salts on steel.
The QP programs that assess painting contractors and shops, and the inspector and applicator certifications for people.
Reading a coating specification
The exposure, often an ISO 12944 category, and the coating system named for it, coat by coat.
Every SSPC, NACE or AMPP document listed with its edition, so nothing is applied from memory.
Blast grade, profile and film thickness compared with the paint manufacturer's data sheet; any conflict goes back as a written question.
Coating hold and witness points written into the inspection and test plan for your inspector.
Your coating inspector joins in person in Vietnam or remotely, with the records in PEB Studio.
Ready for your coating inspector
Who does what on an AMPP coating spec
A coating passes through four sets of hands on a World Steel job. Each one works to the same AMPP documents and hands a record to the next.
AMPP questions on review
Reviewers of an AMPP-based specification look past the products to the documents, the editions and the people.
Which edition of each cited standard was applied?
Each AMPP, SSPC or NACE document is listed with the edition the specification names, before fabrication starts.
Old SSPC or NACE numbers in the spec: still valid?
Yes. The joint numbers carry the same requirement under AMPP, and any edition question goes back as a written query.
Who inspects, and to what qualification?
The inspection the specification names. Your certified inspector can witness every coating hold point in person or remotely.
Is a QP-certified shop required?
Raised before award. No QP certification is held; our inspectors hold FROSIO Level III and BGAS, and how the requirement is met is agreed in writing.
For your coating inspector
Shared before the first member is blasted and kept live in PEB Studio while the job runs.
Every AMPP, SSPC and NACE document in the coating section, with its edition.
SSPC surface preparation →Coating hold and witness points with their acceptance criteria.
How the ITP works →Climate, cleanliness, profile, film thickness and repairs by piece mark.
Coating inspection →Real photos from World Steel
Photographed in our own plant in Tay Ninh Province, Vietnam, and on World Steel jobs. Not stock images.
AMPP never works alone
Each link opens the full page, with its own questions and answers.
What we do not claim
World Steel works to AMPP, SSPC and NACE standards in its own paint shop. Its coating inspectors hold FROSIO Level III and BGAS painting inspector qualifications, not AMPP certification, and the company holds no AMPP QP certification. Where a specification requires either, it is settled before award, for example with an AMPP-certified third-party inspector appointed by you.
Who does what
World Steel designs, fabricates and supplies the steel structure from its own plant in Vietnam. The US contractor, our customer, erects it, has the drawings approved and sealed by their Engineer of Record and pulls the permit.
Details confirmed in quote Edition: The editions your coating specification names
Source record: https://www.ampp.org/
Last checked: —. Editions change on a cycle, so your Engineer of Record confirms which one your jurisdiction enforces.
All US codes & standardsSend it with the drawings. We list every document it cites, compare it with the paint data sheets and return the coating schedule and the hold points for your inspector.