Owners rarely buy a data center on first cost alone. They compare options over ten, fifteen or twenty years, using data center TCO, total cost of ownership, and return on investment. Chapter 6 of the Data Center Handbook edited by Hwaiyu Geng (2nd edition, Wiley, 2021) is a practical guide to those tools. Read alongside the handbook's site selection and structural chapters, it shows an interesting pattern: the structure is one of the smallest lines in the TCO, and one of the longest-lived. This article explains why that matters to anyone buying or building the steel.
What TCO is, in the handbook's words
The handbook describes TCO as a management accounting concept that tries to include as many of the costs of a device, product, service or system as possible, so decisions rest on the best available information. It is often used to choose between options that would all meet the business need. A classic example is comparing two servers: one costs more to buy but uses less power and cooling, and over its life it may be the cheaper choice.
The same logic applies to buildings and their systems. The handbook lists the main components of a TCO or ROI analysis:
- Initial capital investment, including capitalized costs such as site preparation, installation and removal of old equipment;
- Operating costs, especially energy, maintenance and staffing;
- Taxes and other location-dependent costs;
- Additional income, where a project creates revenue or savings;
- End-of-life costs, such as decommissioning and disposal;
- Environmental, brand and reputational costs, including carbon pricing and green energy choices.
Because money has a time value, the handbook explains how to discount future costs and income to present value, and how to compare projects with net present value, internal rate of return, profitability index and break-even time.
The cost picture of a data center
Two observations from other chapters frame where the structure sits.
First, the site selection chapter notes that energy can make up as much as a third of total occupancy cost, and more where rates are high. Operating cost, not construction cost, dominates the life of a data center.
Second, the structural chapter estimates that in an office building the structural system may be around 20% of the shell value, while in a data center it may be as little as about 5% of the shell and core cost, and a fraction of that once the building is fully equipped with power, cooling and IT. The handbook concludes that relatively modest increases in structural capability can have a major effect on performance, so the return on that investment can be significant.
Put the two together and the conclusion is clear. In TCO terms, the steel frame is a small line. But it decides how much roof plant can be added, whether the building survives a hazard event without long downtime, and whether the campus can grow by copying a hall rather than redesigning one.
Mismatched lifetimes
The handbook's site selection chapter points to a deeper issue: IT equipment is refreshed every three to five years, while the facility is expected to last fifteen years or more. The building must accommodate an unknown future. In TCO terms, that means the structure should be valued over the facility's life, not over the first fit-out. A roof sized with reserve capacity, a hung-load allowance that anticipates denser racks, or an expansion wall designed in from the start may look like extra first cost, but over several refresh cycles it avoids rework that would cost far more, both in money and in disruption to a live facility.
Fragmented ownership of cost
Chapter 6 also describes a problem every contractor has seen: responsibility for data center cost is spread across groups that do not talk to each other. Real estate owns the building and pays the power bill, facilities owns the mechanical and electrical plant, IT owns the hardware, and business units own the software. Each group optimizes its own budget.
The structure often falls into the gap. The real estate group may push for the lowest first cost on the shell, while the facilities group later discovers the roof cannot take the more efficient chillers they want. A good TCO analysis brings those groups together early, and the structural design team should be in that conversation.
Making structural decisions with TCO in mind
Here are practical questions that put TCO thinking into the steel package:
- Roof reserve. What is the cost of extra roof capacity now, compared with reinforcing a live roof later?
- Hung-load allowance. What allowance per bay covers busway, tray and containment for several refresh cycles?
- Resilience level. Would designing to a higher risk category, as the handbook suggests for critical facilities, reduce expected losses and downtime enough to justify itself?
- Repeatability. How much engineering, fabrication and inspection effort does a repeatable hall module save across phases?
- Corrosion protection. Does galvanizing or a higher-grade paint system on exposed yard steel cut maintenance over the life of the site?
- Supply chain. What is the landed cost of the steel, including fabrication, coating, packing, ocean freight and import, compared with alternatives? Our landed cost calculator helps teams compare.
These are not abstract. Each can be priced and compared using the handbook's own tools: present value, break-even and risk-adjusted expected loss.
Lower cost without lower quality
Fabricating structural steel overseas is one lever on first cost, provided quality and documentation are controlled. World Steel fabricates in its own plant in Vietnam, with inspection accredited under IAS AC472, mill certificates for every heat of steel and a complete quality record for each shipment. Our page on lower cost, lower risk explains how large US contractors use that lever, and our value engineering approach looks for weight and connection savings without cutting the capacity that protects TCO.
Where World Steel fits
World Steel designs and fabricates structural steel only, for US contractors who erect it and hold the permit; their Engineer of Record approves and seals the design. We do not publish prices: every project gets a written scope and proposal. What we bring to a TCO conversation is a clear structural concept, quantities that match the design criteria, options for reserve capacity priced separately, and shop drawings at no extra charge. See the data center building package and our guide to data center steel structures.
Key takeaways
- The handbook defines TCO as the fullest possible accounting of costs, valued over time with present value methods.
- Energy and operations dominate data center cost; the structure may be about 5% of shell and core cost, and less once equipped.
- Because the frame outlives several IT generations, small extra structural capacity often pays back many times.
- Bring the structural team into TCO discussions early, before fragmented budgets lock in a frame that limits the facility.
Source: H. Geng (ed.), Data Center Handbook, 2nd ed., Wiley, 2021, Chapters 6, 22 and 27. Ideas are paraphrased; consult the handbook and your design team for project decisions.
Quick answers
What does data center TCO include?
The initial capital investment, operating costs such as energy and maintenance, taxes, any additional income, end-of-life costs, and increasingly environmental and reputational costs, all valued over time.
Does World Steel publish prices?
No. Every project gets a written scope and proposal based on its drawings, loads and delivery terms.
Keep building your steel plan
Go further on USPEB.com
On this topic
Across the US market
- US general contractorsHow we support GCs, steel erectors and developers
- Section 232 steel importsDuties and paperwork on imported steel
- Large projects, 2,500 t a monthCapacity for large US general contractors
- Contractor partnershipLong-term supply for US contractors
- Solutions by stateState-by-state steel solutions
- Send your drawingsGet a steel package quote from your drawings


