Double fillet
Most plate girders, built-up columns and rafters. Sized for the shear flow and the AISC 360 minimum for the thinner part joined.
No edge preparation; the web is set square on the flange.
The seam that makes the member
A plate girder, a built-up column or a tapered rafter starts as a web plate and two flange plates. The web-to-flange welds join them along the full length, so the three plates bend as one section. They are the longest welds on any steel package, and most of the tonnage in a large job depends on them. We run them on automatic submerged arc lines, to qualified procedures under AWS D1.1.
Every metre of a built-up member has two to four of these seams. On a 2,500-ton job that is kilometres of weld, so the same settings, fit-up and checks have to hold from the first rafter to the last girder.
Built-up I-section
Section through a welded plate girder. The seams run the full length of the member, on one or both sides of the web.
The plate that carries most of the bending, top and bottom.
The plate between the flanges that carries the shear.
The weld along the web-to-flange joint, one or both sides.
The force per metre the seam passes between web and flange as the member bends.
Three ways to make the seam
The Engineer of Record sets the weld type and size on the design drawings; our shop drawings show each seam with its symbol for your review and approval. Pre-engineered tapered frames often have a fillet on one side only where the frame design allows it; heavier members get both sides.
Most plate girders, built-up columns and rafters. Sized for the shear flow and the AISC 360 minimum for the thinner part joined.
No edge preparation; the web is set square on the flange.
Deep or heavy girders where a fillet would have to be very large, and some heavy columns.
Web edge bevelled to the depth on the shop drawing, then welded to the designed throat.
Crane runway top flanges under heavy cyclic loads, and joints the design needs at full strength.
Ultrasonic testing where the specification calls for it.
AISC 360
Paraphrased from AISC 360. The Engineer of Record runs these checks; we weld to the size and type on the approved drawings.
The force per unit length between web and flange, from the shear, the flange area and the section. The seam must carry it.
A fillet is counted on its throat at 0.60 times the filler metal strength, checked against the base metal.
AISC 360 sets a minimum fillet size by the thinner part joined, from 3 mm (1/8 in) on thin plate to 8 mm (5/16 in) over 19 mm (3/4 in), so enough heat goes in.
Crane wheels and concentrated loads press the flange into the web; the seam or a stiffener carries it.
Under repeated loads, such as crane runways, AISC 360 Appendix 3 may set a weld detail category and inspection.
Single-pass welds only; the size shown on the drawing still governs. Paraphrased from AISC 360 Table J2.4.
AWS D1.1
Paraphrased from AWS D1.1, edition-neutral. Our WPS for each seam is prequalified within these rules or qualified by test with a PQR.
Parts joined by fillet welds are brought as close as practical. The root opening is limited to about 5 mm (3/16 in), and from about 2 mm (1/16 in) the leg is increased by the gap, or the throat is shown to be met.
Flange and web plates are butt spliced with CJP groove welds, ground where needed and inspected, before the web and flanges are welded together.
A prequalified WPS limits the largest fillet made in one pass by process, position and number of wires. Larger seams are built up in passes.
Minimum preheat is set by the steel and the thickest part at the joint, and held along the seam.
Seams start and stop on tabs where the WPS calls for them, so the ends of the member get full weld.
D1.1 sets limits for straightness, camber, sweep, web flatness and flange tilt of welded built-up members. Combined flange warpage and tilt is limited to about b/100 or 6 mm (1/4 in), whichever is greater.
On our beam lines
The sequence every built-up member follows in our plant. No step is skipped for a tight schedule.
Web and flange plates are laser or plasma cut, then spliced with CJP welds that are tested before assembly.
The web is set on the flanges, checked square and tacked tight in the assembly line.
Automatic heads weld both fillets of a joint at once, so heat goes in evenly and the member stays straight.
On tapered rafters and columns the head follows the sloping flange from knee to ridge.
Flange tilt from welding is pressed out and the member is measured against the D1.1 tolerances.
Weld size, profile and member dimensions are recorded under the piece mark.
Inspection
Inspection rates beyond visual are set by your specification and agreed in the Inspection and Test Plan.
Every seam, full length: size with a fillet gauge, profile, undercut, craters and cracks.
Where the specification calls for it, typically on a percentage of seams or at weld ends.
On CJP seams, for example crane runway top flanges, at the rate the specification sets.
Depth, flange tilt, web flatness, camber and sweep measured after straightening.
How it is tested
Every weld is visually inspected by our QC. The other methods run where your specification or the code calls for them, by our QC, by the third party you designate, or, for radiography, through our partner.
The welds inside the seam
Questions
Usually double fillet welds. Heavy girders may use PJP groove welds with a fillet cap, and crane runway top flanges under heavy cyclic loads may be CJP. The Engineer of Record sets the type and size.
From the shear flow the seam must carry, with the minimum size for the thinner part joined from AISC 360. On most members the minimum size or a little more is enough, which is why seams are often smaller than people expect.
Yes, where the frame design allows it. Many tapered rafters and columns are welded one side; heavier members and members with local loads get both sides. The shop drawing shows which.
Parts are brought as close as practical. The root opening of a fillet joint is limited to about 5 mm (3/16 in), and from about 2 mm (1/16 in) the weld leg is increased by the gap, unless the throat is shown to be met.
Before. Flange and web plates are spliced with CJP groove welds and inspected first, then the member is assembled and the seams are welded over the full length.
Every seam is visually inspected along its full length and gauged. MT and UT are added where the specification calls for them, UT mainly on CJP seams such as crane runway top flanges. Member dimensions are checked after straightening.
We will show the seam size, process and tolerances for every built-up member in our quote, from a plant that fabricates 2,500 metric tons a month.