Skip to content
Seeking US contractor partners IAS AC472 ACCREDITED ★ METAL BUILDINGS ★ AC472 IAS AC472 accreditedIAS AC472
World Steel USA

Structural bolts · ASTM A307

The plain bolt behind every purlin lap

Not every joint in a steel building needs a high-strength bolt. Purlin laps, girt clips, flange braces and door framing are held snug by ASTM A307 Grade A bolts, a low-carbon bolt of 415 MPa (60 ksi). A large building has tens of thousands of them, so World Steel counts them from the same model as the frame, bags them by roof and wall line and ships them with the secondary steel, from a plant that fabricates 2,500 metric tons of structural steel a month.

Wall elevation of a steel column with three rows of Z-girts lapped over it and the A307 bolts at each lap circled in red GIRTLAPCOLUMNA307 BOLTS, SNUG-TIGHT
IllustrationNot to scale. Lap lengths and bolt counts come from the design.
2,500 t a month

Purlins, girts and their bolts ride in the same release as the frame they hang on.

Tens of thousands per building

A large warehouse roof and its walls need bolts at every lap and clip.

Bagged by line

Bags are labeled by roof bay or wall elevation, so crews pick the right bag.

Same model, same records

Secondary bolts are listed from the model that places every purlin and girt.

Where it goes

Four kinds of joint A307 bolts hold

Purlin and girt laps

Z-section laps over the frame and the clips that hold them, all snug-tight.

Flange braces

Angles from the purlins to the rafter flange that brace it against buckling.

Door and opening framing

Jambs, headers and sills for framed openings in the walls.

Light secondary steel

Eave struts, base angles and minor framing the design marks snug-tight.

Where it does not go

Three places an A307 bolt never belongs

Never pretensioned

A307 is not a high-strength bolt; it is not used in pretensioned or slip-critical joints.

Not in the main frame

Rafter, column and brace connections of the main frame take F3125 high-strength bolts.

Not in seismic force-resisting joints

Joints of the seismic force-resisting system follow AISC 341 and take pretensioned high-strength bolts.

Main frame joints: A325 bolts. Seismic frames: seismic steel structures.

Grades

A307 Grade A, B and C

Grade A

General-purpose bolts for steel construction; head marked 307A. The grade used in buildings.

Grade B

Heavy hex bolts for cast-iron flanged piping joints. Not a structural steel grade.

Grade C

Once used for anchor rods; withdrawn and replaced by ASTM F1554 Grade 36.

Grade A properties

Minimum tensile strength
415 MPa 60 ksi
Nominal tension, Fnt
310 MPa 45 ksi
Nominal shear, Fnv
188 MPa 27 ksi
Common sizes in metal buildings
12 and 16 mm 1/2 and 5/8 in

Nominal strengths from AISC 360 Table J3.2. Anchor rods: ASTM F1554.

Who does what

A307 bolts: our part and the US contractor's part

World Steel

  • Lists every purlin, girt and brace bolt from the building model
  • Bags bolts, nuts and washers by roof bay and wall line
  • Ships them with the secondary steel they fasten
  • Adds spares for site losses

The US contractor, our customer

  • Engineer of Record confirms which joints are snug-tight
  • Erector installs the secondary steel and snugs the bolts
  • Erector keeps A307 apart from high-strength bolts
  • Owner’s inspector checks the joints the project lists

Secondary steel packed in our plant

Portal frames and roof purlins silhouetted against the sky
Rows of columns, rafters and purlins inside a large steel building
Packing hall with steel bundles, timber dunnage and loading racks
Six-story steel frame seen from the front, floor deck in place

Questions

A307 bolt questions from US contractors

What is an A307 bolt used for?

Snug-tight joints in secondary steel: purlin and girt laps, clips, flange braces and opening framing. It is not used where a joint must be pretensioned.

Is A307 a structural bolt?

It is a carbon steel bolt used in steel construction, but not a high-strength structural bolt. AISC 360 gives it about half the shear strength of an A325.

How is an A307 bolt marked?

Grade A bolts carry 307A on the head with the maker’s mark. A325 and A490 bolts carry their own grade marks.

What replaced A307 Grade C?

Grade C was used for anchor rods and was withdrawn; ASTM F1554 Grade 36 replaced it. See our anchor rod page.

Can A307 bolts be galvanized?

Yes. A307 bolts for galvanized purlins and girts can be supplied hot-dip galvanized with matching nuts.

Are the purlin bolts included with the building?

Yes. Secondary framing bolts are counted from the model and listed in the proposal with the rest of the package.

Roof and wall panel screws: corrosion-resistant fasteners.

Built for large jobs

A307 bolts for your next large package

Our own plant in Vietnam fabricates 2,500 metric tons of structural steel a month, is accredited under IAS AC472 since 2019 and is audited twice a year. Shop drawings are included on every project.

  • 5,000 tSunpro Steel Factory
  • 2,500 tCPV Food Processing Factory
  • 2,000 tLong Son petrochemical complex
  • 2,000 tM&D (MD Factory)
Our large-project program Fillet, CJP and PJP welds on built-up members

Request a quote

Send drawings, a model or a member schedule. Our engineers check the US code basis, size or verify the members and price the fabricated steel, delivered to your US port.

Become our partner in the US

You erect and own the customer; we design, fabricate and ship. Engineering support on your bids and supply under your brand.

Who approves the design. We prepare calculations and drawings ready for your Engineer of Record’s review and approval. The PE seal and the permit stay with the US contractor, our customer.

Shop drawings, included