Our testing promise
Accredited test results for every material, on every project
A mill certificate tells you what the mill found. We add an independent answer: every material on every World Steel project is tested at an ILAC-accredited laboratory, or at the laboratory or place your specification names. The results are filed against the heat or lot they tested, so your Engineer of Record can follow each number to the members it covers.
No material on a World Steel job goes into a member on the strength of a mill certificate alone.
Last reviewed . A guide for US contractors, engineers and inspectors, written by a fabricator. The current edition of each standard named in your specification governs.
Every material, every project
Plate, sections, coil, bolts, welding consumables and coatings: no material on a World Steel job goes untested.
ILAC-accredited laboratories
Tests run at laboratories accredited to ISO/IEC 17025 by an accreditation body that signs the ILAC MRA.
Or the lab you name
If your specification or your Engineer of Record names a laboratory, the samples go there instead.
Traced to your members
Each report is filed against the heat or lot it tested, and through it to the piece marks that use that material.
ILAC MRA, ring by ring
Why an accredited report from Vietnam carries weight in the US
Accreditation is a chain. Each ring checks the one inside it, and the ILAC Mutual Recognition Arrangement ties the outer rings together across borders, so a result from an accredited lab in Vietnam rests on the same system as one from an accredited lab in California.
International Laboratory Accreditation Cooperation
Runs the ILAC Mutual Recognition Arrangement (ILAC MRA). Signatories accept each other’s accredited results as equivalent, and are peer-evaluated to keep their seat.
Regional cooperations
Peer evaluation is organized by region: APAC for Asia Pacific, which includes Vietnam and the United States, IAAC for the Americas, EA for Europe.
National accreditation body
In Vietnam, the Bureau of Accreditation (BoA), whose laboratory program is VILAS. In the US, bodies such as A2LA, ANAB and IAS. Each assesses labs against ISO/IEC 17025.
Accredited laboratory
Accredited for a listed scope of test methods, not for “testing” in general. It reports results with stated uncertainty, traceable calibration and trained staff.
Your test report
Names the method, the sample, the result and the lab’s accreditation. It can carry the accreditation body’s symbol, and with it the ILAC MRA mark.
Three certificates, three meanings
ISO/IEC 17025, ISO/IEC 17020 and ISO 9001 are not interchangeable
A US reviewer sees all three on supplier documents. Only one of them says a test result is right.
ISO/IEC 17025
Testing and calibration laboratories
- What it proves
- The lab is technically competent to run each test method on its scope and to report a valid, traceable result.
- Who holds it on a steel job
- Laboratories that run tensile, Charpy, chemical, bolt and coating tests, and those that calibrate gauges.
ISO/IEC 17020
Inspection bodies
- What it proves
- The body is competent and impartial to inspect and judge conformity: witness tests, inspect welds, review records.
- Who holds it on a steel job
- Third-party inspection firms such as SGS, Intertek and Bureau Veritas, and many US special inspection agencies.
ISO 9001
Quality management systems
- What it proves
- An organization runs a documented quality system. It says nothing about whether a given test result is right.
- Who holds it on a steel job
- Mills, fabricators and suppliers. Useful, but no substitute for an accredited lab’s report.
Four hands on every sample
Who tests what on your steel, from the mill to the hold point
Each party tests something different and hands you a different record. Together they make the material file your Engineer of Record accepts.
How the mill’s own record works is explained on EN 10204 mill test certificates, and the gate check against it on incoming material checks.
On the bench
Nine test families behind a structural steel package
Each one has its own method standard, its own number to read and its own report. Which of them your job needs, and how often, is set in your specification and your Inspection and Test Plan.
Tensile test
ASTM A370 · ASTM E8/E8M
Yield strength, tensile strength and elongation of plate, sections and bars, on a machined specimen pulled to failure.
Chemical analysis
ASTM A751 · ASTM E415
Carbon, manganese, phosphorus, sulfur, silicon and alloy content by spark emission spectrometry; the carbon equivalent follows.
Charpy V-notch impact
ASTM A370 · ASTM E23
Energy a notched 10 × 10 × 55 mm specimen absorbs at the temperature your specification names, three specimens a set.
Hardness
ASTM E10 · ASTM E18 · ASTM E92
Brinell, Rockwell or Vickers hardness of base metal, weld and heat-affected zone, and of bolts, nuts and washers.
Welding qualification coupons
AWS D1.1 · AWS D1.8
Reduced-section tensile, bend and macroetch tests on PQR and welder test coupons, with Charpy where the code or your specification asks.
Nondestructive testing
ASTM E709 · ASTM E165 · AWS D1.1
Magnetic particle, dye penetrant and ultrasonic testing of welds, by technicians qualified to ASNT SNT-TC-1A, to the extent your ITP sets.
High-strength bolt lots
ASTM F3125 · ASTM F606/F606M
Proof load, wedge tensile and hardness of bolts by lot, with nuts to ASTM A563 and washers to ASTM F436.
Coating thickness and adhesion
SSPC-PA 2 · ASTM D7091 · ASTM D4541
Dry film thickness of each coat, surface profile and pull-off adhesion of the paint system your specification names.
Galvanized coating
ASTM A123 · ASTM A153 · ASTM E376
Zinc coating thickness and adherence on hot-dip galvanized members and hardware, measured with magnetic gauges.
For the submittal reviewer
Six checks before you accept a lab report
An accreditation logo on the letterhead is a start. These six checks confirm that the result in front of you is the accredited one, for your material.
The accreditation is current
Find the lab in the accreditation body’s public directory and check the certificate number and expiry date.
The method is on the scope
Accreditation covers listed methods. A lab accredited for tensile tests may not be accredited for Charpy or for coatings.
The body signs the ILAC MRA
Check that the accreditation body is a signatory for testing, so the result carries across borders.
The sample is identified
Heat or lot number, size and location in the product, and who selected and marked the sample.
Results meet the specification
Each value is read against the ASTM grade or code limit, with units and test temperature stated.
The report is signed and whole
Every page numbered, the authorized signatory named, and no result shown without its method.
Third-party inspection
SGS, Intertek and Bureau Veritas on World Steel jobs
All three run accredited laboratories and inspection bodies with staff in Vietnam, so your inspector can be in our plant without flying in from the US. SGS and Intertek have already inspected World Steel projects for our customers.
Founded 1878, headquartered in Geneva, Switzerland
Inspection, testing and certification across most industries, with inspectors and laboratories in Vietnam. On steel jobs: witness testing, product inspection, pre-shipment inspection and 3.2 co-signing.
SGS has inspected World Steel projects for our customers. Appointed by you, or arranged by us at your request.
Headquartered in London, United Kingdom
Testing, inspection and certification with laboratories and inspectors in Vietnam and the US. On steel jobs: vendor inspection, expediting, NDT and material testing in its accredited labs.
Intertek has inspected World Steel projects for our customers. Appointed by you, or arranged by us at your request.
Founded 1828, headquartered near Paris, France
Testing, inspection and certification worldwide, with a long history in marine and industrial steel. On steel jobs: third-party inspection, coating inspection, lab testing and system certification.
Bureau Veritas Vietnam already certifies our welding quality system to EN ISO 3834-2, comprehensive level.
Names are trademarks of their owners and are shown to describe the inspection services a customer can appoint. Any other inspection body or special inspection agency your specification names works with us the same way.
From hold point to data book
How a lab or inspector you appoint works with our plant
The rules are set once, in the Inspection and Test Plan both sides agree before production, and then followed for every heat and lot.
Named in the ITP
Your Inspection and Test Plan names the lab or inspection body, the tests, the sampling rate and every witness and hold point, agreed by both sides before production.
Called in time
We give notice before each hold point, and members are made available in the order your inspector wants them.
Samples marked and witnessed
Samples are cut, marked with the heat or lot number and sealed in front of your inspector, in person or on a live video call.
Tested at the lab
The accredited lab runs the methods on its scope and issues its report, which goes to you and to us at the same time.
Released or held
A pass releases the material. A failure puts it on hold under our nonconformance procedure until the disposition is agreed with your Engineer of Record.
Filed with the steel
Reports join the mill certificates in PEB Studio and the materials volume of your handover documents, filed by heat and lot.
2,500 t
of structural steel fabricated a month in one plant, with jobs up to 5,000 t delivered: Sunpro Steel, CPV Food at 2,500 t, Long Son at 2,000 t.
Testing on large jobs
Hundreds of heats, one test plan
Large US packages are where testing either runs ahead of the shop or holds it up. We plan it as part of the production schedule.
A test matrix, not one-offs
On a large package, testing is planned as a matrix of grades, thicknesses, heats and lots, set in the ITP before the first plate is cut.
Booked ahead of the shop
Sampling and lab slots run ahead of fabrication, so test results never become the thing a 2,500-ton month waits for.
One record for every heat
Hundreds of heats on one job stay sorted: each report is linked to its heat, and each heat to its members, in PEB Studio.
Who does what
Four parties, one material record
Engineer of Record
Sets the tests, rates and acceptance criteria in the specification, accepts the results and decides any failure.
US contractor, our customer
Agrees the ITP with us, appoints any third-party inspector or lab, and brings the records to the building official.
Special inspection agency
Performs the inspections and tests the building official requires under IBC Chapter 17, in the plant or at the site.
World Steel
Buys certified material, has it tested at an ILAC-accredited lab or yours, runs shop QC and files every record against the steel.
Related
The rest of the quality record for your job
Sources
The standards behind this guide
Reviewed November 21, 2026. The current edition of each standard governs.
- ISO/IEC 17025General requirements for the competence of testing and calibration laboratories
- ISO/IEC 17020Requirements for the operation of various types of bodies performing inspection
- ILAC MRAILAC Mutual Recognition Arrangement and the ILAC policy on use of the MRA mark
- ASTM A370Test methods and definitions for mechanical testing of steel products
- ASTM A751Test methods, practices and terminology for chemical analysis of steel products
- ASTM E23Test methods for notched bar impact testing of metallic materials
- ASTM F606/F606MTest methods for determining the mechanical properties of fasteners
- SSPC-PA 2Procedure for determining conformance to dry coating thickness requirements
- AWS D1.1Structural Welding Code, Steel: qualification and inspection
- IBC Chapter 17Special inspections and tests, approved agencies
Questions from US reviewers
Testing lab and third-party inspection questions we hear most
Are the materials for every World Steel project tested at an accredited laboratory?
Yes. Every material for every project is tested at an ILAC-accredited laboratory, meaning one accredited to ISO/IEC 17025 by an accreditation body that signs the ILAC MRA, or at the laboratory or place your specification or your Engineer of Record names. The mill certificate for each heat comes on top of that.
What does ILAC accreditation mean for a test report?
It means the lab was assessed against ISO/IEC 17025 by an accreditation body that is a signatory of the ILAC Mutual Recognition Arrangement. Signatories accept each other’s accredited results as equivalent, so a report from an accredited lab in Vietnam is backed by the same system that backs an A2LA, ANAB or IAS accredited lab in the US.
Is ISO/IEC 17025 the same as ISO 9001?
No. ISO 9001 certifies that an organization runs a quality management system. ISO/IEC 17025 accreditation confirms that a laboratory is technically competent to run specific test methods and report valid results. For a test result, 17025 is the one that counts.
Will our building official accept a test report from a lab in Vietnam?
Acceptance is always the building official’s and your Engineer of Record’s decision. What they usually look for is an accredited lab, a method on its scope, an identified sample and a result against the specification. If your jurisdiction or specification names a US laboratory, samples can be sent there instead.
Can we appoint SGS, Intertek or Bureau Veritas to inspect our order?
Yes, and SGS and Intertek have already inspected World Steel projects for our customers. Your inspector is named in the ITP with the witness and hold points they will attend. We give notice before each point, make the members available and give them access to the records in PEB Studio. If you prefer, we can arrange the firm you choose at your request, with the scope agreed in the proposal.
What is the difference between a testing lab and an inspection body?
A testing laboratory, accredited to ISO/IEC 17025, measures: it runs a tensile or Charpy test and reports the number. An inspection body, accredited to ISO/IEC 17020, judges: it witnesses tests, inspects welds and coatings and reports whether they conform. SGS, Intertek and Bureau Veritas do both, through different accredited units.
Does an EN 10204 3.2 certificate need a third-party inspector?
Yes. A 3.2 is validated by the mill’s inspector and also by the purchaser’s authorized inspector or one designated by regulation, a role firms such as SGS, Intertek or Bureau Veritas often take. It has to be ordered before the steel is made, so it is agreed at the quote stage.
Can testing be witnessed without traveling to Vietnam?
Yes. Sample selection, marking and the tests themselves can be witnessed on a live video call, and the lab report goes to you as soon as it is issued. Many inspectors combine remote witnessing for routine points with one or two visits for the hold points that matter most.
How do we check that a lab is accredited for the test we need?
Look the lab up in its accreditation body’s public directory, BoA’s VILAS list in Vietnam or A2LA, ANAB or IAS in the US, and open its scope of accreditation. The exact test method, for example ASTM A370 tensile or ASTM E23 Charpy, should be listed.
What happens if an independent test fails?
The material goes on hold under our nonconformance procedure. Retests follow the rules of the product specification, and the disposition, whether replace, retest or another solution, is agreed with your Engineer of Record. Nothing on hold is used or shipped until it is released in writing.
Is Smith-Emery the testing lab for our job?
Smith-Emery Laboratories, itself accredited by IAS as inspection agency AA-554, carries out the periodic inspections of our plant for IAS AC472, twice a year since 2019. The lab or agency for your job is the one named in your ITP and specification.
How do test reports reach our submittal?
Each report is filed against the heat or lot it tested, next to the mill certificate, in PEB Studio while the job is in the shop. At handover, reports go into the materials volume of your project documents with the material schedule that ties each heat and lot to its members.
Name your lab, or use ours
Send drawings or a specification with the tests, rates and any third-party inspector you want. We confirm the laboratory, the test matrix and the witness points with the quote.