Who applies it
Certified products, certified hands
UL-certified products
The coating products we apply carry UL certification, and the product on your job is the one named in your coating schedule.
Painters certified by the maker
Our painters are trained and certified by the paint manufacturer on the products they spray.
Batch numbers on record
Product batch numbers are recorded with the coat, so any question goes straight to the manufacturer.
Measured, not assumed
Four readings taken before a member is packed
Each reading is recorded against the piece mark, so your inspector sees the number, not just a tick.
Surface cleanliness
Blast cleaning checked against the grade in your specification before any paint goes on.
Blast profile
The anchor pattern measured so the primer has something to grip.
Dry film thickness
Each coat measured against the thickness on the data sheet and your schedule.
Adhesion
Adhesion tested where your specification calls for it, and recorded with the coat.
How the coating check fits the inspection plan: surface prep and coating checkpoint.
Paint hall rules
Cold or damp air stops the spray guns
Most coating failures start with paint applied in the wrong conditions. These limits are checked before each coat.
- No painting below 4 °C (39 °F) steel or air temperature
- No painting when the steel is within 3 °C (5 °F) of the dew point
- Coats cured to the data sheet before handling and packing
Brands we apply
Coating systems your crew can buy anywhere in the US
We apply coating systems from six international brands. Each sells across the United States, so your crew can buy the exact touch-up product near the job and any warranty question goes to a manufacturer with a US presence.
- JotunNorway
- PPGUnited States
- CarbolineUnited States
- HempelDenmark
- Nippon PaintJapan
- International PaintUnited Kingdom
- Zinc-rich epoxy primers
- High-build epoxy coats
- Polyurethane finish coats
- Epoxy intumescent fire coatings
Brand names are trademarks of their owners and are named only to show the coating systems we apply. No partnership or endorsement is implied. The product on each project is the one named in its coating schedule.
Questions
Questions about shop coatings
Which paint brands do you use?
Coating systems from Jotun, PPG, Carboline, Hempel, Nippon Paint and International Paint, including their epoxy lines. The product on your job is the one named in your coating schedule or specification.
Are your painters certified?
Yes. Our painters are trained and certified by the paint manufacturer, and the coating products we apply carry UL certification.
What do you measure on each coat?
Surface cleanliness and blast profile before painting, dry film thickness on each coat, and adhesion where your specification calls for it. The readings are recorded against the piece mark.
How do we touch up damage after erection?
With the same product named in the coating schedule. Because the brands we use sell across the US, your crew can buy it locally. Touch-up on site is the US contractor’s scope.
Can you apply fire protection coatings?
Yes, epoxy intumescent coatings are among the lines we apply. For fire-rated work, the listed product and thickness named in your design govern.
Do you hot-dip galvanize?
Galvanizing is arranged for members your project specifies as hot-dip galvanized. See the hot-dip galvanizing page for how it is handled.
Send us your coating schedule
We match each system to the brands we apply, confirm the readings your inspector will receive and show how the steel is packed to protect the finish, at a plant that fabricates 2,500 metric tons a month.