Exposure
Open sea upwind is Exposure D, the harshest. At 9.1 m (30 ft) the factor is about 1.16 against 0.98 for open country and 0.70 for a built-up town.
Velocity pressure
Velocity pressure grows with the square of the wind speed. Ten percent more wind gives about twenty-one percent more pressure on the steel. The values below are the basic pressure at 1.0 exposure on flat ground, before the code's pressure coefficients, so you can see how fast the load climbs.
q = 0.613 · Kz · Kzt · Kd · Ke · V²
SI form of the ASCE 7 velocity pressure, in pascals with V in m/s. Kd 0.85 for building frames. Your engineer of record sets V for the island and risk category.
What changes the load
Open sea upwind is Exposure D, the harshest. At 9.1 m (30 ft) the factor is about 1.16 against 0.98 for open country and 0.70 for a built-up town.
Wind speeds up over ridges, hills and escarpments. Hillside villas and hilltop towers on volcanic islands often carry a topographic factor well above 1.0.
Shelters, hospitals and emergency buildings are designed for a longer return period, so the design wind speed rises with the importance of the building.
A building that may lose a door or window in the storm is designed as partially enclosed, with a much larger internal pressure acting with the roof suction.
Codes
Each island decides its own code. Most trace back to the Caribbean Uniform Building Code or to the International Building Code, which takes its wind loads from ASCE 7. We design to the edition the authority and your engineer of record name.
| Code family | Where you meet it | Wind loads from |
|---|---|---|
| CUBiC, Caribbean Uniform Building Code (1985) | The regional model code that shaped many national codes in the Eastern Caribbean | Its own wind section, now often replaced by later editions |
| OECS Building Code | Member states of the Organisation of Eastern Caribbean States | IBC basis with regional provisions |
| National building codes | Jamaica, Barbados, The Bahamas, Trinidad and Tobago and others | National wind provisions, often IBC and ASCE 7 based |
| Puerto Rico Building Code | Puerto Rico | IBC with ASCE 7 wind maps that cover the island |
| International Building Code | US Virgin Islands, Cayman, Bermuda and many private and resort specifications | ASCE 7 |
| Dutch Caribbean and Dominican Republic regulations | Aruba, Curaçao, Sint Maarten and the Dominican Republic | National regulations named by the authority |
Each island's code and approvals are on its own page, from Jamaica to Puerto Rico and Barbados. US loads: ASCE 7 explained.
Load path
A hurricane finds the weakest link. We check every one of them for uplift and for the sideways push, in both wind directions, and list the result in the design report your engineer of record reviews.
Roof uplift in detailSuction peaks at corners and edges; the sheet, its screws and their washers come first.
Spans and spacing tighten in the edge zones; uplift puts the inner flange in compression, so flange braces matter.
Reversing loads every few seconds in a storm, so cleats are bolted, never just tacked.
Frames carry the uplift and the sideways push together; we check both directions.
Rods, angles or portal frames take the wind along the building to the foundations.
Uplift and shear at every column; bolt size, edge distance and embedment go to your foundation engineer.
From our plant
Real World Steel photos from our plant in Vietnam and from buildings we supplied. None is shown as a Caribbean site.
Caribbean hurricane and marine guides
The code, port and parishes of each island are on its own page:
Questions
The one the code and your engineer of record set for the island, the risk category and the site. Puerto Rico and the US Virgin Islands are mapped in ASCE 7; other islands set the value in their national code. We state the speed, exposure and factors in the calculations.
Pressure grows with the square of the speed. Going from 60 to 70 m/s (134 to 157 mph) raises the basic pressure from about 1.88 to 2.55 kPa (39 to 53 psf), a rise of more than a third.
Yes. Open water upwind is Exposure D, the harshest category. At 9.1 m (30 ft) its exposure factor is about 1.16 against 0.70 in a built-up town, so the same wind puts roughly two thirds more pressure on the beachfront building.
When the building may lose a door or window, it is designed as partially enclosed, with a higher internal pressure. The other route is doors and glazing rated for the design wind and debris, which your team buys locally.
No. Hurricane categories describe storms. We design to the wind speed the code sets for the site, which is how authorities and insurers judge a structure.
We give the column reactions, uplift and shear at every base and design the base plates and anchor bolts. The foundations are designed by your engineer.
Send the drawings or the island, site and use. We set the wind basis with your engineer of record, design the steel load path end to end and quote it made in our plant in Vietnam and shipped to your port.