Washington · Cascadia seismic
Structural steel for Washington’s earthquake country
Western Washington sits above the Cascadia subduction zone, with crustal faults such as the Seattle fault running under the Puget Sound cities and deep, soft soils in the river valleys and tideflats. Most commercial and industrial sites there land in a high seismic design category. The frame, its connections and its welds are designed for it from the first sketch.
Made in World Steel’s own plant in Vietnam, the first and only fabricator in Vietnam accredited under IAS AC472, and shipped to a Washington port.
Design datum
- Hazard
- Cascadia subduction, crustal faults and deep intraslab quakes
- Loads
- ASCE 7 seismic for your site class and risk category
- Systems
- Designed to AISC 341 where the design requires it
- Welds
- Demand-critical welds by AWS D1.8 qualified welders
Why it matters
Three kinds of earthquake, one frame
Washington faces three sources of strong shaking: the Cascadia subduction zone offshore, able to produce a magnitude 9 event with long shaking; shallow crustal faults like the Seattle and Tacoma faults under the cities; and deep intraslab quakes such as the 2001 Nisqually earthquake. ASCE 7 folds them into the ground motions for your site, and soft soils in the Duwamish, Puyallup and Kent valleys can amplify them or liquefy.
For a steel structure that usually means a seismic force-resisting system with ductile detailing: special or ordinary concentrically braced frames, moment frames, or a metal building system within its code limits. Where the system falls under AISC 341, the members, connections, welds and material toughness all carry extra requirements, and we fabricate to them.
What we design and fabricate
The seismic details a Washington frame needs
Braced and moment frames
Seismic force-resisting systems sized to the response modification factor your Engineer of Record selects.
Ductile connections
Brace and beam connections detailed so the frame yields where the design intends, not at a weld or bolt.
Demand-critical welds
Welds identified on the drawings and made by welders qualified to AWS D1.8, with records per weld.
Protected zones
Zones marked on the drawings and, on request, on the steel, so no attachment is welded there on site.
Material toughness
Plate and filler metal with the toughness AISC 341 requires, and EN 10204 3.1 certificates with impact values on request.
Anchorage
Base plates and anchor rods designed for overstrength forces, with reactions tabled for the foundation engineer.
Who does what
Seismic work, split clearly
World Steel prepares
- Seismic design of the steel structure to ASCE 7 and AISC 341 where required
- Calculations and drawings for your Engineer of Record to review
- Demand-critical welds and protected zones shown on the shop drawings
- Welding records, mill certificates and inspection reports per member
- Remote access for your inspector to follow fabrication, on request
The US contractor arranges
- Engineer of Record approval and the PE or SE seal
- The geotechnical report, site class and any site-specific study
- Special inspection on site and the building permit
- Erection, field welds and bolting to the drawings
- Foundations and anchor rod setting
What we do not claim
World Steel holds no Washington State, City of Seattle or county approval of its own, and no building is earthquake-proof. Seismic systems are designed and fabricated to AISC 341 and AWS D1.8 where the design requires them; the Engineer of Record seals the design and the building official approves it.
Washington ecosystem
Products and solutions behind this guide
The World Steel products, systems and services this guide relies on, made in our plant in Vietnam.
Real World Steel photos
World Steel at work
Real photos from our plant in Vietnam, where the steel for your Washington project is cut, welded, inspected and packed.
Q&A
What Washington buyers ask
Which seismic design category will my site be in?
It depends on the site class from your geotechnical report and the risk category of the building. Many Puget Sound sites land in Seismic Design Category D; your Engineer of Record confirms it, and we publish no value per city.
Can you fabricate special concentrically braced frames?
Yes. We fabricate braced and moment frames to AISC 341 where the design requires them, with AWS D1.8 qualified welders, demand-critical welds identified and protected zones marked.
Do you have seismic experience?
Yes. We design and fabricate to AISC 341 and AWS D1.8 for US projects and have supplied buildings in Guam, which is also highly seismic. We do not claim a completed building in Washington.
Official sources: Washington Geological Survey: earthquakes and faults
Washington solutions
Every Washington guide
Related pages
Code facts on this page summarize Washington rules, the International Building Code, ASCE 7 and related standards for US buyers. They are not legal or engineering advice; your Engineer of Record and building official confirm the edition and local amendments in force for your permit.
Building in Washington?
Send the drawings or the site address, size and use. We set the Washington design basis with your Engineer of Record, design or detail the steel and quote it made in our plant in Vietnam, packed in erection order for your site.