Oklahoma · Seismic

Structural steel for Oklahoma seismic design

Central and north-central Oklahoma saw a sharp rise in earthquakes in the 2010s, and the state now takes seismic design seriously for large buildings. The seismic design category depends on the site class and the risk category, so it is confirmed for every address rather than assumed for the state.

Made in World Steel’s own plant in Vietnam, the first and only fabricator in Vietnam accredited under IAS AC472, 2,500 t a month, and landed at Port Houston and trucked north to your Oklahoma site.

Built-up members with welded stiffeners and drilled clip plates on shop supports
Stiffeners and drilled clip plates welded on, World Steel plant in Vietnam.
Region
Central and north-central
Decides
Site class and risk category
Most affected
Bracing and anchorage
Our part
Category per site

Why it matters

Confirm the category, then detail

Seismic loads for most Oklahoma buildings are moderate, but the seismic design category still changes the steel: which bracing systems are allowed, how the connections are detailed and how the base plates and anchor rods are designed. Soft soil and a high risk category can move a site into a higher category.

We take the site class from your geotechnical report, confirm the category with your Engineer of Record and detail the braces, connections and anchorage for it. Where the design calls for seismic detailing under AISC 341, our shop works with AWS D1.8-qualified procedures and welders.

What we design and fabricate

Steel for seismic design

Bracing

Braces and gussets for the chosen lateral system.

Anchorage

Base plates and anchor rods for seismic shear and uplift.

Diaphragms

Roof bracing and collectors that tie the frame together.

Documented welds

AWS D1.8-qualified procedures where required.

Who does what

Seismic design, split clearly

World Steel supplies

  • Bracing, connection and anchorage design or detailing
  • Seismic detailing to the stated category
  • Weld procedures and welder qualifications on request
  • Mill certificates traced by heat
  • Tekla shop and erection drawings, included

The US contractor arranges

  • Geotechnical report and site class
  • Engineer of Record approval and PE seal
  • Special inspections where required
  • Local permit and inspections
  • Erection and site work

Oklahoma

What we do not claim

World Steel claims no AISC 341 certification. Seismic detailing is designed to AISC 341 where the design requires it and checked by your Engineer of Record.

Oklahoma ecosystem

Products and solutions behind this guide

The World Steel products, systems and services this guide relies on, made in our plant in Vietnam.

Open call · Oklahoma contractors

Oklahoma contractors: let’s win the next project together

If your next bid involves seismic design, World Steel wants to be your long-term, win-win steel partner in Oklahoma. You win the job and build it; we design, fabricate and supply the structural steel from our own plant in Vietnam.

Real World Steel photos

World Steel at work

Real photos from our plant in Vietnam, where the steel for your Oklahoma project is cut, welded, inspected and packed.

Welder looking over the stiffeners and end plate of a heavy column
Column stiffeners and end plate under inspection at World Steel, Vietnam.
Welded members with drilled end plates laid out side by side
Members with drilled end plates waiting for release, Vietnam plant.
Tubular column with a square base plate and bolt holes, crew working behind it
Column with its base plate and anchor-bolt holes, fabricated in the Vietnam plant.
Gray members stacked and strapped together on a packing rack
Gray members strapped into a bundle on the packing rack, World Steel, Vietnam.

Q&A

What Oklahoma buyers ask

Is all of Oklahoma a seismic zone?

No. Activity has been highest in central and north-central Oklahoma. The category is confirmed for every site from its soil and risk category.

Does seismic design change the steel much?

Mostly the bracing, connections and anchorage. The category decides which systems and details are allowed.

Can you supply AISC 341 detailing?

Yes, where the design requires it, with AWS D1.8-qualified welding procedures and welders.

Official sources: Oklahoma Geological Survey: earthquakes · USGS Earthquake Hazards

Oklahoma solutions

Every Oklahoma guide

Related pages

Code facts on this page summarize Oklahoma practice, the IBC as adopted by the Oklahoma Uniform Building Code Commission, ASCE 7 and related standards for US buyers. They are not legal or engineering advice; your Engineer of Record and the local building department confirm the code and edition in force for your project.

Building in Oklahoma?

Send the drawings or the site address, size and use. We set the Oklahoma design basis with your Engineer of Record, design or detail the steel to the statewide code and to tornado, hail, ice and seismic loads, and quote it made in our plant in Vietnam, packed in erection order for the trip to your site.