Exported steel in place in Singapore: a World Steel job abroad, shown for the building type rather than a US site.
Florida · Flood zones
Steel buildings for Florida flood zones and storm surge
In a hurricane, water often does more damage than wind. Much of coastal Florida sits in FEMA special flood hazard areas, where storm surge, waves and heavy rain set the lowest floor, the foundation type and what can be built below it. Your design team sets the design flood elevation; we shape the steel around it.
Made in World Steel’s own plant in Vietnam, the first and only fabricator in Vietnam accredited under IAS AC472, and shipped to a Florida port.
- Flood maps
- FEMA Flood Insurance Rate Maps: zones V, VE, Coastal A, AE, A and X
- Standard
- ASCE 24 through the Florida Building Code, plus local floodplain rules
- Key number
- Design flood elevation, set by your engineer and the community
- Steel role
- Elevated frames, raised platforms, breakaway walls and vented enclosures
Flood zones
What each zone means for a steel building
| Zone | What it means | What it means for the steel |
|---|---|---|
| V and VE | Coastal high hazard area, with waves of 0.9 m (3 ft) or more | Elevate on piles or columns, keep the area below open or use breakaway walls; no dry floodproofing |
| Coastal A | Waves of 0.45 to 0.9 m (1.5 to 3 ft), landward of the LiMWA line | ASCE 24 applies many V-zone foundation rules; open or breakaway lower walls are common |
| AE and A | One-percent-annual-chance flood, mainly still water | Elevate the floor, or dry floodproof a non-residential building; vented enclosures below the flood level |
| X (shaded and unshaded) | Moderate or minimal flood hazard | No federal rules, but heavy rain still needs drainage and raised thresholds |
Design options
How steel helps on a flood-prone site
Elevated platforms
Steel floor framing on columns lifts the occupied floor above the design flood elevation while parking or storage stays below.
Breakaway walls
Light wall panels and girts below the flood level designed to break away under waves without damaging the frame, as ASCE 24 describes.
Flood openings
Enclosures below the flood level get openings so water levels equalize, sized by engineering or at about 6,944 mm² per m² of enclosed area (1 sq in per sq ft).
Galvanized lower members
Columns and bracing that can be wetted by flood water are galvanized or given a heavier system.
Reactions for deep foundations
Pile and pier foundations get our column reactions, including combined wind and flood cases your engineer specifies.
Raised openings
Door sills, equipment and electrical rooms set above the flood level where the plan allows.
Who sets the flood design
Flood loads, scour, buoyancy and the design flood elevation are set by your design team under ASCE 24 and your community’s floodplain ordinance, which often adds freeboard. We design and supply the steel to those criteria; we do not certify elevations or flood-proofing.
Florida ecosystem
Products and solutions for this condition
The World Steel products, systems and services this guide relies on, made in our plant in Vietnam.
Real World Steel photos
World Steel at work
Florida solutions
Other Florida guides
Questions
What Florida buyers ask
Can a metal building go in a V zone?
Yes, if it is elevated on an open foundation with nothing but breakaway walls, parking, access or storage below the design flood elevation. Steel frames suit this well.
Can we dry floodproof a steel warehouse?
Non-residential buildings in A zones can be dry floodproofed under ASCE 24, with walls and shields designed for the flood loads. That design comes from your engineer; we frame the building to suit it.
Where do I find my flood zone?
On FEMA’s Flood Map Service Center and through your county’s floodplain administrator, who also tells you any local freeboard rule.
Official sources: FEMA Flood Map Service Center
Keep reading
Related pages
Code facts on this page summarize the Florida Building Code, ASCE 7-22 and related standards for US buyers. They are not legal or engineering advice; your Engineer of Record and building official confirm the edition and local amendments in force for your permit.
Building in Florida?