Skip to content
Seeking US contractor partners IAS AC472 ACCREDITED ★ METAL BUILDINGS ★ AC472 IAS AC472 accreditedIAS AC472
World Steel USA

Tennessee · New Madrid seismic

Seismic structural steel for West Tennessee and Memphis

The New Madrid seismic zone runs under the Mississippi Valley just north of Memphis, and the soft river soils around the city amplify shaking. Many West Tennessee sites land in Seismic Design Category C or D, where the bracing, the connections and some welds must be detailed for ductility. The category comes from the site soils, so two parcels in the same county can differ.

Made in World Steel’s own plant in Vietnam, the first and only fabricator in Vietnam accredited under IAS AC472, and delivered to your Tennessee site through the East Coast or West Coast ports.

Columns and floor beams of a multi-story steel frame partway through erection
Going up beside the plant in Vietnam: World Steel framed its own office building.
Hazard
New Madrid seismic zone
Most affected
Memphis and West Tennessee
Design basis
ASCE 7 and AISC 341 where it applies
Our part
Seismic detailing at design stage

Why it matters

A Midwest fault with Memphis on its doorstep

Large earthquakes struck the New Madrid zone in 1811 and 1812, and the USGS maps it as one of the highest seismic hazards east of the Rockies. Memphis sits on deep, soft sediments that can amplify ground motion, which is why the site soil class matters as much as the distance to the fault.

Once a building lands in a high Seismic Design Category, AISC 341 governs the lateral system: braced or moment frames with ductile details, protected zones, demand-critical welds and capacity-designed connections. Your Engineer of Record sets the category and the system; we design and detail the steel to it.

What we design and fabricate

Seismic steel for West Tennessee

Braced frames

Special or ordinary concentrically braced frames sized to the system your engineer picks.

Moment frames

Prequalified moment connections to AISC 358 where open bays are needed.

Demand-critical welds

Welds made by AWS D1.8-qualified welders with procedures on file.

Anchorage

Base plates and anchor bolts designed for seismic shear and uplift, with reactions tabled.

Protected zones

Yielding regions marked and kept free of welds, holes and attachments.

Material records

Mill certificates by heat, with Charpy toughness on request.

What changes

How the Seismic Design Category changes the steel

Typical effects; your Engineer of Record decides the system for your building.

CategoryTypical lateral systemDetailing
A or BOrdinary braced or moment framesStandard AISC 360 connections
COrdinary systems, often with limitsAISC 341 may apply to parts of the system
D and aboveSpecial braced or moment framesAISC 341 detailing, demand-critical welds, protected zones

What we do not claim

We publish no seismic value per site and claim no seismic rating for a building. The Seismic Design Category comes from your geotechnical report and Engineer of Record; inspections follow IBC Chapter 17 with the special inspector your project hires.

Tennessee ecosystem

Products and solutions behind this guide

The World Steel products, systems and services this guide relies on, made in our plant in Vietnam.

Open call · Tennessee contractors

Tennessee contractors: let’s win the next project together

If your next bid involves New Madrid seismic, World Steel wants to be your long-term, win-win steel partner in Tennessee. You win the job and build it; we design, fabricate and supply the structural steel from our own plant in Vietnam.

Real World Steel photos

World Steel at work

Real photos from our plant in Vietnam, where the steel for your Tennessee project is cut, welded, inspected and packed.

Welder looking over the stiffeners and end plate of a heavy column
Column stiffeners and end plate under inspection at World Steel, Vietnam.
Welded members with drilled end plates laid out side by side
Members with drilled end plates waiting for release, Vietnam plant.
Tubular column with a square base plate and bolt holes, crew working behind it
Column with its base plate and anchor-bolt holes, fabricated in the Vietnam plant.
Built-up members with welded stiffeners and drilled clip plates on shop supports
Stiffeners and drilled clip plates welded on, World Steel plant in Vietnam.

Q&A

What Tennessee buyers ask

Is all of Tennessee high seismic?

No. The hazard is highest in West Tennessee near Memphis and falls off toward the east. The category for your building depends on the site soils and the risk category, set by your Engineer of Record.

Can you weld to AWS D1.8?

Yes. Our shop holds AWS D1.8-qualified welding procedures and welders for demand-critical welds, with records kept per piece.

Do seismic details add a lot of steel?

They mostly change connections and bracing, not the tonnage of the whole frame. We compare options with your engineer early so the system fits the building.

Official sources: USGS: New Madrid seismic zone

Tennessee solutions

Every Tennessee guide

Related pages

Code facts on this page summarize Tennessee practice, the International Building Code, ASCE 7 and related standards for US buyers. They are not legal or engineering advice; your Engineer of Record and building official confirm the edition and local amendments in force for your permit.

Building in Tennessee?

Send the drawings or the site address, size and use. We set the Tennessee design basis with your Engineer of Record, design or detail the steel and quote it made in our plant in Vietnam, packed in erection order for the trip to your site.